Table 2. Summary of systematic and random positional errors stratified by region of interest used for CBCT image registration.
Target | Nose | |||||
LR (mm) | CC (mm) | AP (mm) | LR (mm) | CC (mm) | AP (mm) | |
Localization CBCT | ||||||
Group Mean | -0.54 | 0.06 | -1.24 | -0.83 | -0.33 | -1.80 |
Systematic Error | 0.47 | 1.18 | 0.50 | 0.52 | 1.74 | 0.28 |
Random Error | 0.78 | 1.08 | 0.53 | 0.88 | 1.29 | 0.52 |
Verification CBCT | ||||||
Group Mean | 0.04 | -0.18 | -0.02 | -0.31 | -0.53 | -0.63 |
Systematic Error | 0.16 | 0.14 | 0.17 | 0.47 | 0.81 | 0.68 |
Random Error | 0.32 | 0.34 | 0.32 | 0.46 | 0.65 | 1.09 |
Post-Treatment CBCT | ||||||
Group Mean | 0.04 | -0.06 | -0.19 | -0.33 | -0.36 | -0.68 |
Systematic Error | 0.25 | 0.18 | 0.22 | 0.53 | 0.70 | 0.48 |
Random Error | 0.38 | 0.43 | 0.40 | 0.48 | 0.58 | 0.47 |