Skip to main content
. 2016 Jan 12;37(15):1220–1227. doi: 10.1093/eurheartj/ehv690

Table 4.

Comparison of different models for discrimination of ischaemia (FFR ≤0.80; N = 484 vessels)

Model Wald test, P-value AUC (95% CI)
Model 1: Stenosis >50% Comparison with no effect, <0.001 0.71 (0.67–0.76)
Model 2: Stenosis >50% + LD-NCP ≥30 mm3 Comparison with Model 1, <0.001 0.79 (0.74–0.84)
Model 3: Stenosis >50% + LD-NCP ≥30 mm3 + FFRCT ≤0.80 Comparison with Model 2, <0.001 0.90 (0.87–0.93)

FFR, fractional flow reserve; AUC, area under the receiver-operating characteristics curve; CI, confidence interval; LD-NCP, low-density non-calcified plaque; FFRCT, fractional flow reserve derived from coronary computed tomography angiography.