Skip to main content
British Heart Journal logoLink to British Heart Journal
. 1978 May;40(5):530–533. doi: 10.1136/hrt.40.5.530

Long-term follow up of cardiac pacing threshold using a noninvasive method of measurement.

I D Starke
PMCID: PMC483440  PMID: 656220

Abstract

Seventeen patients were followed up for a period ranging from 12 to 40 months after implantation of an Elema Vario pacemaker with an endocardial electrode. Two patients had a greater stimulation threshold beyond 6 months after implantation than the maximum threshold recorded before 6 months. One of these patients required replacement of the pacing system because of exit block. The 16 patients who retained their pacing systems showed, as a group, a statistically significant fall in stimulation threshold at 12 months after implantation despite continued pacing. These findings are important in relation to the occurrence and prediction of late exit block when long-life impulse generators are used.

Full text

PDF
530

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. ALBERT H. M., GLASS B. A., PITTMAN B., ROBICHAUX P. CARDIAC STIMULATION THRESHOLD: CHRONIC STUDY. Ann N Y Acad Sci. 1964 Jun 11;111:889–892. doi: 10.1111/j.1749-6632.1964.tb53158.x. [DOI] [PubMed] [Google Scholar]
  2. Berning J., Larsen B. Permanent pacemaker treatment at Gentofte hospital. A follow-up study with special reference to transvenous electrode complications, generator longevity and control procedures. Acta Med Scand Suppl. 1976;596:35–39. [PubMed] [Google Scholar]
  3. Brenner A. S., Wagner G. S., Anderson S. T., Rosati R. A., Morris J. J., Jr Transvenous, transmediastinal, and transthoracic ventricular pacing: a comparison after complete two-year follow-up. Circulation. 1974 Mar;49(3):407–414. doi: 10.1161/01.cir.49.3.407. [DOI] [PubMed] [Google Scholar]
  4. Contini C., Papi L., Pesola A., L'Abbate A., Magini G., D'Angelo T., Cinacchi P., Maseri A., Donato L. Tissue reaction to intracavitary electrodes: effect on duration and efficiency of unipolar pacing in patients with A-V block. J Cardiovasc Surg (Torino) 1973 May-Jun;14(3):282–290. [PubMed] [Google Scholar]
  5. Davies J. G., Sowton E. Electrical threshold of the human heart. Br Heart J. 1966 Mar;28(2):231–239. doi: 10.1136/hrt.28.2.231. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. Gadaleta G., Knippel M., Carù B., Ranzi C. Il comportamento della soglia di eccitabilità endocardica durante LA STIMOLAZIONE ELETTRICA PERMANENTE. Boll Soc Ital Cardiol. 1971;16(1):43–46. [PubMed] [Google Scholar]
  7. Green G. D. Assessment of cardiac pacemakers: pacemaker frontal plane vectors. Am Heart J. 1971 Jan;81(1):1–6. doi: 10.1016/0002-8703(71)90048-2. [DOI] [PubMed] [Google Scholar]
  8. Grendahl H., Schaanning C. G. Variation in pacing threshold. A study in patients with external pacemaker and unipolar endocardial electrode. Acta Med Scand. 1970 Jan-Feb;187(1-2):75–78. [PubMed] [Google Scholar]
  9. Marchand P., Jaros G. G., Obel I. W. Long-pulse stimuli for cardiac pacing. Ann N Y Acad Sci. 1969 Oct 30;167(2):706–717. doi: 10.1111/j.1749-6632.1969.tb34131.x. [DOI] [PubMed] [Google Scholar]
  10. Preston T. A. Chronic threshold measurement. Ann Cardiol Angeiol (Paris) 1971 Jul-Aug;20(4):501–502. [PubMed] [Google Scholar]

Articles from British Heart Journal are provided here courtesy of BMJ Publishing Group

RESOURCES