Table 1.

HPLC conditions

Compound Eluent Flow rate (mL/min) Retention time (min)
Preparative
 CB184 Acetonitrile:H2O (6:4) 6 9.1
 CB190 Acetonitrile:H2O (55:45) 6 10.1
Analytical
 CB185 Acetonitrile:H2O (7:3) 1 7.8
 CB190 Acetonitrile:H2O (65:35) 1 8.0

Conditions employed for preparative and analytical HPLC are shown. Preparative HPLC was carried out using a Capcellpak C18 UG120S-5 μm column (10 mm inner diameter (i.d.) × 250 mm, Shiseido, Tokyo, Japan) and a JASCO HPLC system (JASCO, Tokyo, Japan) installed within the radiosynthesis system. Analytical HPLC was conducted using a Capcellpak C18 UG120S-5 μm column (4.8 mm i.d. × 250 mm, Shiseido, Tokyo, Japan) and a Shimadzu HPLC system (Shimadzu, Kyoto, Japan) with gamma ray detection using NaI(Tl) scintillator