Table 1.

Reported Measurements of T1 in WM at 7T

Study Reported WM T1 (ms) Region Sequence and Parameters
Li and Deoni (4) 1500 ± 100 Not stated DESPOT1, flip angle = 5°/10°/20°
Rooney et al. (5) 1220 ± 36 Frontal Look-Locker, 32 TIs, 20 ms to 10 s
Ikonomidou et al. (6) 1357 ± 22 Not stated IR-EPI, TIs 30–8000 ms
Wright et al. (7) 1017 ± 86 Cortical IR-FSE, 9 TIs, 120–2000 ms
Wright et al. (8)a ~1250? Cortical IR-EPI, 9 TIs, 120–4000 ms
Wright et al. (8) 1130 +/100 Cortical MPRAGE, 8 TIs, 160–2100 ms
Grinstead and Rooney (9) 1180 ± 40 Not stated IR-EPI, TI values not reported
Marques et al. (10) 1150 ± 60 Frontal MP2RAGE, TI = 1000/3300 ms
Marques et al. (10) 1110 ± 60 Corpus callosum MP2RAGE, TI = 1000/3300 ms
Dortch et al. (11) 1372 Global mean Selective IR qMT, 15 TIs, 6 ms to 2s
Dieringer et al. (12) 1284 ± 22 Global mean IR-FSE, 8 TIs, 60–5000 ms
Dieringer et al. (12) 1855 ± 141 Global mean 2D VFA, flip angle = 3°/8°/25°

Abbreviations: DESPOT1, driven equilibrium single point observation of T1; IR-EPI, inversion recovery echo planar imaging; IR-FSE, inversion recovery fast spin echo; MPRAGE, magnetization prepared rapid acquisition of gradient echo; MP2RAGE, magnetization prepared 2 rapid acquisition gradient echoes; qMT, quantitative magnetization transfer; VFA, variable flip angle.

a

The measurement using IR-EPI is not reported in the text but is inferred from Figure 5 in Wright et al. 2008.