The dimensional changes (mean and standard deviation) of the three denture base materials over time.

Base material Time
After 4 months After 8 months After 12 months
Mean SD Mean SD Mean SD
Acrylic resin fabricated by conventional technique 1.52 0.014 1.56 0.018 1.59 0.02
Acrylic resin fabricated by injection moulding technique 1.58 0.019 1.6 0.022 1.63 0.027
Cobalt chrome metallic 1.5 0.01 1.5 0.01 1.5 0.01

Statistically significant.