Skip to main content
. Author manuscript; available in PMC: 2017 May 1.
Published in final edited form as: Ear Hear. 2016 May-Jun;37(3):354–364. doi: 10.1097/AUD.0000000000000261

Table 2.

Columns on the left show p- and F-values from a 1-way ANOVA analysis based on the mean modulation detection threshold at each point in time. P values indicate the probability that the threshold remained the same over time. Values less than 0.05 are considered statistically significant. The columns on the right show the mean thresholds averaged over all times, and the mean 95% confidence intervals at each frequency, averaged across points in time.

Frequency of modulation P value F4 value Mean Threshold Mean 95% confidence
10 Hz 0.02 3.40 −20.02 2.91
50 Hz 0.56 0.76 −13.02 3.36
100 Hz 0.55 0.78 −9.70 3.29
150 Hz 0.29 1.33 −5.70 3.12
200 Hz 0.42 1.03 −3.63 2.23
300 Hz 0.67 0.59 −2.40 1.65