Skip to main content
. Author manuscript; available in PMC: 2016 Apr 28.
Published in final edited form as: AJR Am J Roentgenol. 2015 Nov;205(5):1026–1037. doi: 10.2214/AJR.14.14185

TABLE 3.

Percentage Agreement Between Organ- and Structure-Specific Diagnosis Codes From the Three Half-Dose Configurations and the Full Dose Plus Filtered Back-Projection (FBP) Configuration in CT Examinations of Three Abdominopelvic Organs (Liver, Kidney, and Small Bowel)

Organ, Reader Absolute Agreement, % (No./Total)
Normality Agreement, % (No./Total)
FBP SAFIRE aNLM FBP SAFIRE aNLM

Liver
 Reader 1 80 (20/25) 92 (23/25) 92 (23/25) 88 (22/25) 92 (23/25) 96 (24/25)
 Reader 2 92 (23/25) 96 (24/25) 100 (24/24) 96 (24/25) 100 (25/25) 100 (24/24)
 Reader 3 92 (23/25) 88 (22/25) 88 (22/25) 92 (23/25) 88 (22/25) 88 (22/25)
 All readers 88 (66/75) 92 (69/75) 93 (69/74) 92 (69/25) 93 (70/75) 95 (70/74)
Kidney
 Reader 1 88 (22/25) 76 (19/25) 96 (24/25) 100 (25/25) 84 (21/25) 100 (25/25)
 Reader 2 96 (24/25) 96 (24/25) 96 (24/25) 96 (24/25) 96 (24/25) 96 (24/25)
 Reader 3 100 (25/25) 92 (23/25) 100 (25/25) 100 (25/25) 92 (23/25) 100 (25/25)
 All readers 95 (71/75) 88 (66/75) 97 (73/75) 99 (74/75) 91 (68/75) 99 (74/75)
Small bowel
 Reader 1 88 (22/25) 88 (22/25) 88 (22/25) 96 (24/25) 92 (23/25) 96 (24/25)
 Reader 2 96 (23/24) 100 (24/24) 96 (23/24) 100 (24/24) 100 (24/24) 100 (24/24)
 Reader 3 72 (18/25) 72 (18/25) 83 (20/24) 84 (21/25) 84 (21/25) 83 (20/24)
 All readers 85 (63/74) 86 (64/74) 89 (65/73) 93 (69/74) 92 (68/74) 93 (68/73)

Note—The three half-dose configurations were FBP, sinogram-affirmed iterative reconstruction (SAFIRE, Siemens Healthcare), and adaptive nonlocal means (aNLM). Absolute agreement was the percentage of cases with absolute agreement between diagnosis codes. Normality agreement occurred if both the full-dose and the half-dose configurations were normal or if both were not normal.