. 2016 Apr 15;16(4):542. doi: 10.3390/s16040542

Table 3.

Electrocardiogram signal quality—freshwater immersion without movement condition.

Parameter Ag/AgCl PLS p-Value Ag/AgCl PLP p-Value
Temporal measures of HRV meanNN (ms) 840.0 ± 155.6 828.0 ± 97.8 0.8358 778.0 ± 275.1 746.9 ± 119.1 0.4171
SDNN (ms) 112.9 ± 64.0 53.5 ± 13.8 0.0223 225.4 ± 135.2 72.8 ± 27.6 0.0044
RMSSD (ms) 144.9 ± 101.7 54.5 ± 20.0 0.0271 304.5 ± 189.0 75.9 ± 41.8 0.0027
NN50 61.37 ± 39.28 43.0 ± 33.6 0.3318 162.33 ± 108.57 102.88 ± 99.19 0.2429
Spectral measures of HRV LF (ms2) 3809 ± 3317 1105 ± 686 0.0404 11390 ± 15613 1514 ± 1238 0.0767
HF (ms2) 7168 ± 7290 886 ± 600 0.0292 24366 ± 38574 1678 ± 2052 0.0971
Total (ms2) 667061 ± 15484 638996 ± 15272 0.7205 584884 ± 181314 492856 ± 147666 0.2549
LF/HF 1.03 ± 0.74 1.42 ± 0.66 0.2799 0.62 ± 0.29 1.47 ± 0.89 0.0154
Corr-Coef r (unitless) 0.41 ± 0.23 0.96 ± 0.02 0.0000 0.41 ± 0.23 0.93 ± 0.04 0.0000