Skip to main content
. 2016 May 4;139(5):2372–2385. doi: 10.1121/1.4947044

FIG. 8.

FIG. 8.

The trajectories along the middle suture row (r3) for all three larynges are given for the adduction level MP100. Corresponding PS values as given in Table III. For L3, suture l1 showed only noisy behavior and was therefore excluded for analysis. Trajectories represent the motion of the complete analyzed 110 ms interval (L1: 18 cycles; L2: 22 cycles, L3: 15 cycles).