Skip to main content
. 2016 May 3;3(1):e000089. doi: 10.1136/bmjgast-2016-000089

Table 1.

Intention to diagnose per-patient performance of second-generation capsule colonoscopy in the detection of polyps

Polyp size (mm) Polyp prevalence n (%) CC2 per segment matching analysis
(N=50 patients) Sensitivity
% (95% CI)
Specificity
% (95% CI)
≥6 15 (30%) 93.3 (66.0 to 99.7) 80.0 (62.5 to 90.9)
≥10 7 (14%) 100.0 (56.1 to 100.0) 93.0 (79.9 to 98.2)

CC2, second-generation capsule colonoscopy.