3 |
Incorrect protonation of ligand |
ADT currently uses Babel to add hydrogen positions, which makes occasional errors |
Double-check the PDBQT file and manually curate errors in protonation |
4 |
Missing coordinates in receptor |
Experimental coordinate sets are heterogeneous. Common problems include missing side chains and loops, asymmetric units that include only a portion of the biological unit, alternate conformations, essential cofactors and structural waters. |
Double-check the PDBQT file and manually curate to include the proper biological unit. In general, use the biological unit and omit ligands and waters except for strongly-bound prosthetic groups. |
5(A)iii |
Vina does not run |
ADT “Start Vina” GUI or command line is not using the proper path to the Vina executable, or file is incorrect CPU or operating system type. |
Locate the Vina executable on your computer, and use the appropriate path name. Refer to online installation notes to locate the executable. |
5(A)iii |
No low energy conformations are found |
Grid box does not enclose the active site |
Choose an appropriate location for the grid box in ADT |
5(B)ii |
AutoGrid does not run |
ADT “Run AutoGrid” GUI or command line is not using the proper path name to the AutoGrid4 executable, or file is incorrect CPU or operating system type. |
Locate the AutoGrid executable on your computer, and use the appropriate path name. Refer to online installation notes to locate the executable. |
5(B)v |
AutoDock does not run |
ADT “Run AutoDock” GUI or command line is not using the proper path name to the AutoDock4 executable, or file is incorrect CPU or operating system type. |
Locate the AutoDock executable on your computer, and use the appropriate path name. Refer to online installation notes to locate the executable. |
5(B)vi |
Re-docking experiments do not reproduce the known pose |
System has too many degrees of freedom for AutoDock conformational search |
Use longer search protocols, or simplify the system by reducing degrees of freedom (docking in parts or rigidifying part of the ligand) |
5(C)i |
Problems with selection |
Right-click is used in several places in Raccoon for selection – use control-click on Macintosh computers |
Use “System Preferences” on Macintosh computers to enable right clicking for the mouse or trackpad, |
5(C)vi |
No results selected during filtering by interaction |
Residue names are case sensitive |
Use all capitals, such as THR315 |
5(D)iv |
No low energy conformations are found |
Grid box does not enclose all of the side chains |
Choose a larger grid box that encloses the binding side and all of the flexible side chains |
5(F)iv |
Error message about missing W parameters |
Water dummy atom parameters not defined in force field parameter file and/or docking parameter files |
Ensure that the modified files are used |