Skip to main content
. 2016 Jun;6(2):181–190. doi: 10.1086/686020

Table A2.

Intraclass correlation coefficients (ICCs) using a 2-way mixed model for consistency and absolute agreement

Intraoperator Interoperator
A1, A2 A1, B1 A2, B1
Variable and model type ICC 95% CI ICC 95% CI ICC 95% CI
RAC (%)
 Consistency 0.982 0.956–0.993 0.943 0.858–0.977 0.96 0.903–0.984
 Absolute agreement 0.98 0.947–0.992 0.943 0.858–0.977 0.9 0.903–0.984
Wb/Wtot
 Consistency 0.993 0.982–0.997 0.986 0.965–0.994 0.987 0.966–0.995
 Absolute agreement 0.993 0.983–0.997 0.985 0.961–0.994 0.986 0.966–0.994
Rd, mmHg s/mL
 Consistency 0.998 0.994–0.999 0.993 0.82–0.997 0.992 0.98–0.997
 Absolute agreement 0.998 0.994–0.999 0.99 0.959–0.997 0.99 0.971–0.996
C, mL/mmHg
 Consistency 0.985 0.962–0.994 0.931 0.834–0.972 0.901 0.768–0.96
 Absolute agreement 0.983 0.955–0.993 0.926 0.821–0.97 0.887 0.719–0.955
Note

P < 0.001. CI: confidence interval; RAC: relative area change; Wb/Wtot: ratio of wave power; Rd: distal resistance; C: pulmonary compliance.