Skip to main content
. 2016 May 17;11(5):e0155670. doi: 10.1371/journal.pone.0155670

Table 2. MR Imaging Parameters.

Sequence Repetition Time (ms) Echo Time (ms) Flip Angle (°) Slice Thickness (mm) Field of View (cm) Matrix Size Acquisition Duration/ Time Resolution (s) Imaging Planes Additional Information
Perfusion MR Fat-saturated T1-weighted FFE 3.6 1.8 15 (pre); 15 (post) 6.0 25 × 25 208 × 206 3.0 Axial or coronal 100 dynamics (5 min)
Screening and pretreatment planning T2-weighted 3D TSE with DRIVE 1000.0 135.0 90 2.5 25 × 25 168 × 120 200–220 Sagittal SENSE 1.8
MR thermometry RF-spoiled segmented EPI 37.0 19.5 19 7.0 40 × 25 160 × 100 2.9 Coronal, sagittal 121-binomial water-selective excitation
Immediate follow-up* Fat-saturated T1-weighted THRIVE 6.6 3.2 10 2.5 28 × 28 240 × 240 170–190 Coronal SENSE 1.5

DRIVE, driven equilibrium; EPI, echo planar imaging; FFE, fast field echo; MR, magnetic resonance; RF, radiofrequency; SENSE, sensitivity encoding; THRIVE, T1-weighted high resolution isotropic volume examination; TSE, turbo spin echo

* Gd-DOTA (0.1 mmol/kg; Dotarem, Guerbet, Aulnay-sous-Bois, France) was used for contrast enhancement.