Skip to main content
. 2016 May 19;11(5):e0155612. doi: 10.1371/journal.pone.0155612

Table 4. Rotation angles for transforming loads from the femur- to the implant-based coordinate system and implant neck lengths.

αx, αy and αz = orientation of the implant relative to the femur coordinate system in frontal, sagittal and transverse planes (see Fig 1). L = neck length from head centre to intersection of neck and stem axis (see Fig 1). Data from 10 individual subjects and their average.

Implant Orientation Neck Length
Relative to Femur System
Subject αx [°] αy [°] αz [°] L [mm]
H1L 2.3 -2.3 -15.0 55.6
H2R 4.1 0.6 -13.8 59.3
H3L 4.0 -3.0 -13.8 55.6
H4L 7.5 -1.7 -18.9 63.3
H5L 4.0 -2.3 -2.3 55.6
H6R 5.8 -1.7 -31.0 55.6
H7R 6.3 -1.7 -2.4 63.3
H8L 4.6 -1.7 -15.5 59.3
H9L 4.6 0.6 -2.3 59.3
H10R 1.7 -1.2 -9.7 59.6
Average 4.5 -1.4 -12.5 58.7