Table III.

Predictive value of each parameter baseline values and RIs using ROCs analysis. Only parameters for which a significant correlation was found [see appendix, to be found online, at http://www.informahealthcare.com/doi/abs/10.3109/0284186X.2012.702923] are included.

Parameter* AUC Cut-off value Sensitivity (%) Specificity (%) Sensitivity for 100% specificity (%) Cut-off value
SUVmax RI3 (%) 0.77 −43 88   58 31 −16
SUVmaxPVC RI3 (%) 0.73 −33 50   83 13   −5
SUVmean PET1 0.75 6.1 50 100 50   6.1
RI2 (%) 0.73 −31 88   33 50 −10
RI3 (%) 0.79 −34 81   67 31 −11
SUVmeanPVC PET1 0.76 7.3 44 100 44   7.3
RI2 (%) 0.77 −33 81   25 50   −8
RI3 (%) 0.75 −42 88   58 19   −8
TLG RI2 (%) 0.75 −34 56   67 56 −23
RI3 (%) 0.79 −53 63   92 38 −37
TLGPVC RI2 (%) 0.70 −34 56   50 44 −18
RI3 (%) 0.78 −54 63   92 31 −38