Table 3. Response to steroida treatment in patients with narrow-caliber and regular-caliber esophagus.
Narrow-caliberb (n = 39) | Regular-caliber (n = 310) | P valuec | |
---|---|---|---|
Symptom response to steroids (n, %) | 14 (56) | 175 (85) | <0.01 |
EGD response to steroids (n, %) | 17 (52) | 146 (76) | <0.01 |
Histologic response to steroids (n, %) | 11 (33) | 119 (63) | <0.01 |
Maximum eosinophil count before steroids (median, IQR) eos/hpf | 77.5 (33-100) | 60.0 (37-100) | 0.38 |
Maximum eosinophils after steroids (median, IQR) eos/hpf | 45 (3-90) | 3 (0-34) | <0.01 |
Defined as any topical swallowed corticosteroid formulation.
Characterized by inability to pass an adult upper endoscope.
P values for significant difference in distribution of proportions and P value for difference in maximum eosinophil count.