Table 3. Free-response receiver operating characteristic (FROC) and receiver operating characteristic (ROC) analysis in the sentinel lymph node experiment.

FROC analysis 1 FP 2 FP
Sensitivity (incl. ITC) 0.71 (0.39–0.93) 0.74 (0.59–0.94)
Sensitivity (excl. ITC) 0.90 (0.63–0.99) 0.93 (0.78–1.0)
ROC analysis Area under the curve Specificity at 99.9% sensitivity
Test (incl. ITC) 0.88 (0.77–0.97) 0.39 (0.33–0.90)
Test (excl. ITC) 0.90 (0.79–0.98) 0.39 (0.32–0.94)
consecutive (incl. ITC) 0.74 (0.65–0.82) 0.02 (0.01–0.30)
consecutive (excl. ITC) 0.88 (0.81–0.93) 0.44 (0.43–0.69)

Mean bootstrap values are given for sensitivity (FROC analysis), area under the curve (ROC analysis) and specificity at 99.9% sensitivity (ROC analysis). 95th-percentile confidence intervals obtained through bootstrapping are shown between brackets. (FP = False positive detections per tumor-negative image).