Skip to main content
. 2016 May 23;6:26409. doi: 10.1038/srep26409

Table 3. Comparison of average deviation of simulated current with respect to measured current for all sequences and two simulation scenarios (Run1– σ MAX was optimised, other parameters were fixed for all sequences, Run2 – all parameters fixed for all sequences).

Seq. N IMAX [A] Run1 – optimised σMAX
Run2 – same parameters
avg. ΔI [A] avg. ΔI/IMAX avg. ΔI [A] avg. ΔI/IMAX
1 0.732 0.036 4.9% 0.058 7.9%
2 0.825 0.031 3.6% 0.059 7.2%
3 0.888 0.033 3.7% 0.043 4.8%
4 1.422 0.043 3.0% 0.059 4.1%
5 1.412 0.039 2.8% 0.072 5.1%
6 1.597 0.050 3.1% 0.062 3.9%
7 2.015 0.045 2.2% 0.047 2.3%
8 2.005 0.041 2.0% 0.090 4.5%
9 2.302 0.063 2.7% 0.094 4.1%