Skip to main content
. 2016 May 5;3(1):e000102. doi: 10.1136/bmjresp-2015-000102

Table 4.

Organisational issues; training and equipment

Ambulance crews n=68 Nurses n=22 Doctors n=22
Have you had any specific training in oxygen use? (Number saying ‘Yes’) 34/47 15/15 9/15
Do you think you have had adequate training in oxygen use? 26/43 9/15 11/17
When treating patients with acute exacerbations of COPD, do you have access to the following equipment (usually or always)
Answers given as per cent of those who replied
Simple face mask 92 100 93
Reservoir mask 98 100 88
Nasal cannulae 63 42 75
24% Venturi mask 45 28 60
28% Venturi mask 59 53 49
Oxygen driven nebuliser 94 100 88
Air-driven nebuliser 33 0 37
Finger oximeter 100 93 100

COPD, chronic obstructive pulmonary disease.