Skip to main content
. Author manuscript; available in PMC: 2016 Nov 1.
Published in final edited form as: J Neurointerv Surg. 2015 Nov 26;8(11):1140–1147. doi: 10.1136/neurintsurg-2015-012050

TABLE 3.

Multiple Comparisons of Area-Averaged Velocity at Aneurysm Neck Plane among Pre-embolized, Stented, and Post-coiled Models

Means ± SD, m/s P value
Pre-embolized model versus stented model 0.31±0.10 versus 0.27±0.09 <0.001
Pre-embolized model versus post-coiled model 0.31±0.10 versus 0.25±0.09 <0.001
Stented model versus post-coiled model 0.27±0.09 versus 0.25±0.09 0.662

Data expressed as mean± standard deviation.