Skip to main content
. 2016 May 16;16(5):705. doi: 10.3390/s16050705

Table 2.

Cutting parameters assessment conditions for quality optimization (Layer 1).

Setup Nominal Microchannel Width wnom (μm) Nominal Microchannel Wall Width wwall (μm) Cutting Load fload (N) Cutting Passes N Material Nominal Depth dnom (μm)
I 750 500 0.8 2 75
II 750 500 1.0 1 75
III 750 500 1.0 1 50
IV 750 500 0.8 2 50
V 200 500 0.8 2 75
VI 200 500 1.0 1 75
VII 200 500 0.8 2 50
VIII 200 500 1.0 2 50