Fig. 3.

Fig. 3

Examples of EEG recording and corresponding probability of reactivity of cases with different expert labels: (A) Reactive case with corresponding high probability value. (B) Non-reactive case with corresponding low probability values. (C) Reactive case with a discrepant low probability value (misclassification) (D) Unclear case with median probability value. Top frames reflect the spectrogram of the pre- and post-stimulation epoch in Cz-Pz, showing the power (dB) of the frequency components (Freq) in time. Onset of stimulation is at 60s, as indicated by the double vertical lines in the spectrum. Lower curves display the Cz-Pz recording in time, where the blue line (0–60 s) reflects the pre-stimulation epoch and the red line the post-stimulation epoch (60–120 s). In the side panel, the probability calculated using the FC3 final model is shown. (For interpretation of the references to colour in this figure legend, the reader is referred to the web version of this article.)