Skip to main content
. 2016 May 31;11(5):e0152442. doi: 10.1371/journal.pone.0152442

Table 1. Test Methods Evaluated, with Range and Measurement Increment.

Test Manufacturer Test Method Range (mg/L) Measurement Increment (mg/L)
Digital Titration Hach Company Titration 20–70000 2.5
WataTest Antenna Titration 1000–7000 500
Pooltester (Cylinder Dilution) Palintest DPD 0–6 Low level: 0.1, High level: 0.5
Pooltester (Pipette Dilution) Palintest DPD 0–6 Low level 0.1, High level 0.5
Color Wheel (Cylinder Dilution) Hach Company DPD 0–3.4 0.2
Color Wheel (Pipette Dilution) Hach Company DPD 0–3.4 0.2
Indigo Indigo Labs Test Strip 0–10,000 0, 1000, 2500, 5000, 7500, 10000
Activate Activate Test Strip 0–10,000 0, 1000, 2500, 5000, 7500, 10000
Precision Extra Precision Labs Test Strip 0–10,000 0, 1000, 2500, 5000, 7500, 10000
Serim Serim Monitor Test Strip 100–750 100, 200, 350, 500, 750
Precision High Precision Labs Test Strip 0–1,000 0, 50, 100, 250, 500, 1000
WW Ultra I Waterworks Test Strip 0–750 0, 25, 100, 200, 300, 400, 500, 750
WW Ultra II Waterworks Test Strip 0–2,000 0, 25, 50, 200, 500, 800, 1100, 1500, 2000
InstaTest LaMotte Test Strip 0–800 0, 50, 100, 250, 500, 800