Skip to main content
. 2016 May 26;11:1105–1118. doi: 10.2147/COPD.S102222

Table S1.

Correlation coefficient (r) between FOT parameters and conventional lung function test

Resistive parameters
Reactive parameters
R6 R20 RAvr FDep X6 X20 XAvr Fres
Airflow parameters
FEV1 −0.49* −0.07 −0.28* 0.61* 0.61* 0.63* 0.67* −0.66*
Raw 0.41* 0.06 0.26* −0.49* −0.48* −0.54* −0.55* 0.57*
FEF25–75% −0.48* −0.05 −0.27* 0.62* 0.56* 0.61* 0.65* −0.64*
Lung volume parameters
FVC −0.46* −0.21* −0.36* 0.43* 0.47* 0.48* 0.52* −0.47*
IC −0.40* −0.22* −0.32* 0.32* 0.44* 0.44* 0.46* −0.44*
RV 0.07 0.24* −0.10 −0.31* −0.24* −0.31* −0.26* 0.28*
TLC −0.11 −0.31* −0.24* −0.11 −0.05 −0.08 −0.05 0.06
RV/TLC 0.29* 0.06 0.12 −0.45* −0.43* −0.49* −0.45* 0.45*

Notes:

*

P<0.05. The figures illustrate Spearman correlation coefficient (r).

Abbreviations: FDep, frequency dependence; FEV1, forced expiratory volume in 1 second; FOT, forced oscillation technique; Fres, resonance frequency; FVC, forced vital capacity; IC, inspiratory capacity; R6, resistance at 6 Hz; R20, resistance at 20 Hz; RAvr, average resistance; Raw, airway resistance; RV, residual volume; TLC, total lung capacity; X6, reactance at 6 Hz; X20, reactance at 20 Hz; XAvr, average reactance.