Table 2.
Control (n=5–7) | Aortic‐Banded Sedentary (n=5–7) | Aortic‐Banded Exercise Trained (n=5–7) | |
---|---|---|---|
Ejection fraction, % | 64±3 | 66±3 | 65±4 |
Septum wall thickness, mm | 10.8±0.4 | 12.1±0.3a | 11.8±0.5a |
Left ventricle plus septum mass, g | 140±6 | 171±6b | 186±10b |
End‐diastolic volume, mL | 105±11 | 103±9 | 103±7 |
Left ventricle plus septum to end‐diastolic volume ratio | 1.3±0.1 | 1.8±0.2b | 1.7±0.1b |
End‐diastolic pressure–volume relationship, mm Hg/mL | 0.005±0.001 | 0.011±0.002b | 0.014±4b |
P=0.078 vs control.