ECG, Pressure–Volume Loop, and Postmortem Measures of Cardiac Parameters

Control (n=5–7) Aortic‐Banded Sedentary (n=5–7) Aortic‐Banded Exercise Trained (n=5–7)
Ejection fraction, % 64±3 66±3 65±4
Septum wall thickness, mm 10.8±0.4 12.1±0.3a 11.8±0.5a
Left ventricle plus septum mass, g 140±6 171±6b 186±10b
End‐diastolic volume, mL 105±11 103±9 103±7
Left ventricle plus septum to end‐diastolic volume ratio 1.3±0.1 1.8±0.2b 1.7±0.1b
End‐diastolic pressure–volume relationship, mm Hg/mL 0.005±0.001 0.011±0.002b 0.014±4b
a

P=0.078 vs control.

b

P<0.05 vs control.