Fig. 4.

Fig. 4

Temporal effect of regeneration steps on power performance of an individual MFC. A – Step 1: addition of the alkaline lysis solution. B – Step 2: replacing the outer layer with the same loading of carbon. C – Power output improvement from sequential treatment of the cathodic biofilm with chemical lysis; data are from a separate experiment under batch conditions. Blue arrows indicate points of feeding with urine.