Skip to main content
. Author manuscript; available in PMC: 2016 Jun 7.
Published in final edited form as: Appl Opt. 2015 Sep 1;54(25):7612–7621. doi: 10.1364/AO.54.007612

Table 1.

Recovered μaf for First Simulation Study

Case No. Inclusion Size (mm) Depth (mm) True μaf (mm−1) Conventional FT
TM-FT
μaf (mm−1) FWHM (mm) x/y μaf (mm−1) FWHM (mm) x/y
1 4 5 0.01 0.0031 3.9/7.1 0.0077 4.0/4.8
2 4 10 0.01 0.0024 4.2/8.0 0.0079 4.0/4.4
3 4 20 0.01 0.0017 4.5/10.4 0.0078 3.8/4.6
4 3 20 0.01 0.0014 4.3/10.4 0.0094 3.0/4.2
5 7 20 0.01 0.0048 5.4/10.8 0.0090 7.0/7.2