Table 3.
Mean and standard deviation of pore water concentration (WCPore), collagen-bound water concentration (WCCollagen) and mineral-bound water concentration (WCMineral) using UTE imaging techniques, THO-H2O isotope exchange study and gravimetric analysis, respectively.
| Pore Water (WCPore) |
Collagen-Bound Water (WCCollagen) |
Mineral-Bound Water (WCMineral) |
WCPore + WCCollagen | WCPore + WCCollagen + WCMineral |
|
|---|---|---|---|---|---|
| UTE Measured WCTotal | - | - | - | 21.0 ± 2.8% | - |
| IR-UTE Measured WCCollagen | - | 17.9 ± 1.6% | - | - | - |
| Pore Water (WCTotal – WCCollagen) | 4.7 ± 0.5% | - | - | - | - |
| UTE + Bi-Component Analysis | 5.3 ± 0.4% | 15.7 ± 2.3% | - | - | - |
| THO-H2O Exchange | 5.9 ± 0.6% | 18.1 ± 2.1% | 9.5 ± 0.6% | - | 33.5 ± 0.6% |
| Gravimetric Analysis | 6.3 ± 0.8% | 19.2 ± 3.6% | - | 25.5 ± 0.6% | - |