. 2015 Oct 30;26:2118–2125. doi: 10.1007/s00330-015-4062-z

Table 1.

Sequence parameters

T2-weighted FSE Diffusion-weighted MRI
DWIBS DWI-SPIR DWI-SPAIR
Repetition time 8456–9558 4808–4829 4971 4172–5241
Echo time 130–150 70 70 68–70
Number of slices 22–30 50 24 20–24
Slice thickness (mm) 3–5 5 5 5
FOV (mm) 200 440 320 320
Acquired in plane resolution (mm × mm) 0.78 × 1.14 2.50 × 3.11–3.18 1.82 × 2.31 1.82 × 2.27
Sensitivity encoding factor 1.9–2 1.9 1.9
Echotrain length 25 1 1 1
Number of signal averages 2–6 4 5 5
Acquisition time (min:sec) 4:37–6:30 10:37–12:20 05:33 05:51–06:44
B-values 0, (100), 500, 1000 0, 500, 1000 0, (25, 50, 100) 500,1000
Fatsuppression technique STIR SPIR SPAIR
Echo planar imaging factor 53–55 55 61

Abbreviations: STIR short TI inversion recovery, SPIR spectral presaturation with inversion recovery, SPAIR spectral attenuated inversion recovery. During the study period, the DWIBS sequence was applied from September 2008 through December 2011, the DWI-SPIR sequence was used from December 2011 through June 2012, and the DWI-SPAIR sequence was used from June 2012 through the end of the study period (July 2014)