Skip to main content
. 2016 Jun 13;9:124. doi: 10.1186/s13068-016-0544-8

Table 1.

Half-lives of wild-type TlGlu16A and its mutants for thermal inactivation

Enzyme t 1/2 (min) at
65 °C 70 °C 75 °C 80 °C
TlGlu16A 25 3 1 0.5
H58D 77 56 37 31
E134R 41 3 4.5 7
D235G 39 4 3.5 25
D296K 60 15 30 22

The enzyme activity was assayed at each optimal condition for 10 min