Skip to main content
. 2016 May 26;12(1):692–698. doi: 10.3892/ol.2016.4633

Table III.

Average dose values (Gy) in the clinical target volume.

Technique Median Dmin (range)a Median Dmax (range)b Median Dmean (range)c Median Dmod (range)d Median Dmed (range)e
2-field   43.0 (41.1–44.7) 50.2 (46.5–53.8)   46.8 (45.1–49.2)   46.5 (45.2–48.2)   46.0 (45.1–49.1)
3-field   43.3 (41.2–44.6) 50.3 (46.1–55.9) 46.9 (45–50.1) 46.6 (45–50.1) 46.9 (45–49.4)
4-field   43.6 (42.5–44.9) 49.0 (46.1–50.5) 46.2 (45–47.6) 45.9 (44.2–47)   46.1 (45.1–47.5)
IMRT 43.0 (41–44.1) 48.7 (46.3–52.4)   46.0 (44.5–47.2)   45.9 (44.2–47.3)   46.0 (44.5–47.3)

IMRT, intensity-modulated radiation therapy.

a

P=0.001

b

P<0.001

c

P=0.010

d

P=0.110

e

P=0.010. Median Dmin, median of all minimum doses; median Dmax, median of all maximum doses; median Dmean, median of all mean doses; median Dmod, median of all modal doses; median Dmed, median of all median doses.