Skip to main content
. 2016 Jun 15;7:942. doi: 10.3389/fmicb.2016.00942

Table 5.

Escherichia coli O104:H4 detection from artificially contaminated milk samples in the presence of contaminating bacteria (L. monocytogenes, C. jejuni, and S. aureus): comparison between the EU RL VTEC official method and the E. coli O104 Dynabeads method.

E. coli O104:H4 in the initial suspension (CFU number) Contaminating bacteria in the initial suspension (CFU number) E. coli O104:H4 isolated with EU RL method (CFU number) E. coli O104:H4 isolated with the E. coli O104 Dynabeads method (CFU number) S. aureus isolated with the E. coli O104 Dynabeads method (CFU number on Blood Agar plate) L. monocytogenes isolated with the E. coli O104 Dynabeads method (CFU number on Blood Agar plate) C. jejuni isolated with the E. coli O104 Dynabeads method (CFU number on Karmali Agar plate)
106 103 >200 >200 0 0 0
105 103 >200 >200 0 0 0
104 103 137 >200 0 0 0
103 103 41 121 0 0 0
102 103 6 19 0 0 0
101 103 0 1 0 0 0