Table 6. Case Study 2: Tone Burst Auditory Brainstem Response Testing Results at Diagnosis (in Decibels of normal hearing level [nHL]).
Frequency (Hz) | ||||
---|---|---|---|---|
500 | 1,000 | 2,000 | 4,000 | |
Right | 40 | DNT | 60 | 70 |
Left | 40 | DNT | 70 | 80 |
Abbreviation: DNT, did not test.
Note: Thresholds at 1 kHz are interpolated from the thresholds at 0.5 and 2 kHz.