Study Protocol Training intensity index Number of participants Average age Modality Electrodes position
1 Allen et al., 2001 Alpha− 5.0 20 28 Auditory T3, F7
2 Becerra et al., 2012 Theta− 15.0 7 65 Auditory F4, C3, C3, P3, F7, F8
3 Berner et al., 2006 Beta1+ 0.3 6 21 Auditory Cz
4 Bird et al., 1978 Gamma+ 8.0 11 23 Auditory O1, O2
5 Bird et al., 1978 Gamma− 8.0 11 23 Auditory O1, O2
6 Boxtel van et al., 2012 Alpha+ 8.6 15 21 Auditory C3 C4
7 Chisholm et al., 1977 Alpha+ 1.0 12 21 Auditory Oz
8 DeGood and Chisholm, 1977 Alpha+ 1.0 10 20 Auditory Pz
9 Egner et al., 2002 Alpha−/theta+ 1.7 9 23 Auditory Pz
10 Enriquez-Geppert et al., 2013 Theta+ 10.0 16 25 Visual Fz, FC1, FCz, FC2, Cz
11 Enriquez-Geppert et al., 2014 Theta+ 8 19 24 Visual Fz
12 Hoedlmoser et al., 2008 SMR+ 10.0 16 24 Mixed C3
13 Keizer et al., 2010a Gamma+ 7.0 8 23 Auditory Oz, Fz
14 Keizer et al., 2010b Gamma/beta− 6.1 7 22 Auditory Oz
15 Kober et al., 2015 SMR+ 7 10 24 Visual Cz
16 Konareva, 2005 Alpha−/theta+ 1.0 30 22 Auditory C3/C4
17 Landers and Petruzzello, 1991 SCP+ 0.2 8 no data Visual No data
18 Logemann et al., 2010 SMR+/theta− 5.3 14 21 Mixed No data
19 Peeters et al., 2014 Alpha− 1 16 22 Visual F3
20 Reichert et al., 2015 SMR+ 10 28 45 Mixed Cz
21 Reis et al., 2015 Alpha+ 6 8 60 Visual Fz
22 Reis et al., 2015 Theta+ 6 8 60 Visual Fz
23 Ring et al., 2015 Alpha− 1 12 23 Auditory Fz
24 Ros et al., 2010 Alpha+ 1.0 12 31 Visual C3
25 Ros et al., 2010 Beta1+ 1.0 12 31 Visual C3
26 Ros et al., 2013 Alpha− 0.2 17 33 Visual C4
27 Wang and Hsieh, 2013 Theta+ 6.0 16 65 Mixed Fz
28 Witte et al., 2013 SMR+/theta− 2.7 10 24 Visual Cz

In a few articles the authors did not supply sufficient information regarding the experimental paradigm (denoted as ‘no data’ in the table). The “+” and “–” signs in the “Protocol” column denote the enhancement or suppression of particular frequency bands.