Table 2.
In vitro studies of non-irradiated and irradiated allograft tissue for anterior cruciate ligament reconstruction
| Ref. | Year | Type of study | Graft type | Irradiation dose | Temperautre when irradiated | No. of samples | Age (yr) | Findings |
| Balsly et al[9] | 2008 | Laboratory | BPTB - low dose | 1.83-2.18 Mrad | - 20 °C to -50 °C | 9 | 18-55 | There was a significant difference for: (1) BPTB - tensile strength in the moderate dose irradiation vs control groups (2) Fascia lata - modulus of elasticity in the moderate dose irradiation vs control groups |
| BPTB - moderate dose | 2.4-2.85 Mrad | 9 | ||||||
| BPTB - control | None | N/A | 9 controls for low dose | |||||
| 9 controls moderate dose | ||||||||
| Anterior Tibialis - low dose | 1.83-2.18 Mrad | - 20 °C to -50 °C | 10 | 23-64 | No significant difference between the tensile strength and modulus of elasticity for all other groups for low dose irradiation vs control and moderate dose irradiation vs control (other than stated above) | |||
| Anterior Tibialis - moderate dose | 2.4-2.85 Mrad | 10 | ||||||
| Anterior Tibialis - control | None | N/A | 10 controls for low dose | |||||
| 10 controls for moderate dose | ||||||||
| Semitendinosus - low dose | 1.83-2.18 Mrad | - 20 °C to -50 °C | 8 | 16-54 | ||||
| Semitendinosus - moderate dose | 2.4-2.85 Mrad | 10 | ||||||
| Semitendinosus - control | None | N/A | 10 controls for low dose | |||||
| 10 controls for moderate dose | ||||||||
| Fascia Lata - low dose | 1.83-2.18 Mrad | - 20 °C to -50 °C | 10 | 19-48 | ||||
| Fascia Lata - moderate dose | 2.4-2.85 Mrad | 10 | ||||||
| Fascia Lata - control | None | N/A | 10 controls for low dose | |||||
| 10 controls for moderate dose | ||||||||
| Greaves et al[17] | 2008 | Laboratory | Tibialis - single strand irradiated (age < 45) | 1.46-1.8 Mrad | Dry ice temperatures | 10 irradiated | < 45 | No significant difference in failure loads for irradiated vs non-irradiated for each of the three age groups (midsubstance failure = any rupture within graft substance, grip failure = slip from 1 of tendon grips exposing serrated portion of tendon) |
| Tibialis - single strand non-irradiated (age < 45) | 10 non-irradiated | |||||||
| Tibialis - double strand irradiated (age < 45) | 10 irradiated | |||||||
| Tibialis - double strand non-irradiated (age < 45) | 10 non-irradiated | |||||||
| Tibialis - single strand irradiated (age 46-55) | 13 irradiated | 46-55 | ||||||
| Tibialis - single strand non-irradiated (age 46-55) | 13 non-irradiated | |||||||
| Tibialis - double strand irradiated (age 46-55) | 10 irradiated | |||||||
| Tibialis - double strand non-irradiated (age 46-55) | 10 non-irradiated | |||||||
| Tibialis - single strand irradiated (age 56-65) | 10 irradiated | 56-65 | ||||||
| Tibialis - single strand non-irradiated (age 56-65) | 10 non-irradiated | |||||||
| Tibialis - double strand irradiated (age 56-65) | 10 irradiated | |||||||
| Tibialis - double strand non-irradiated (age 56-65) | 10 non-irradiated | |||||||
| Baldini et al[34] | 2012 | Laboratory | Tibialis | 2.0-2.8 Mrad | Not reported | 15 | 41.8 | There were no significant difference in stiffness, failure to load, and failure stress between the irradiated vs non-irradiated groups |
| None | 12 | 47.4 | ||||||
| Yanke et al[35] | 2013 | Laboratory | BPTB | 1.0-1.2 Mrad | Not reported | 10 | 52 ± 11 | There was a significant difference in stiffness between the irradiated vs non-irradiated groups but none found in strain and elongation |
| None | 10 |
BPTB: Bone patella tendon bone.