Skip to main content
Scientific Reports logoLink to Scientific Reports
. 2016 Jun 17;6:28029. doi: 10.1038/srep28029

FEV manoeuvre induced changes in breath VOC compositions: an unconventional view on lung function tests

Pritam Sukul 1, Jochen K Schubert 1, Peter Oertel 1, Svend Kamysek 1, Khushman Taunk 2, Phillip Trefz 1, Wolfram Miekisch 1,a
PMCID: PMC4911606  PMID: 27311826

Abstract

Breath volatile organic compound (VOC) analysis can open a non-invasive window onto pathological and metabolic processes in the body. Decades of clinical breath-gas analysis have revealed that changes in exhaled VOC concentrations are important rather than disease specific biomarkers. As physiological parameters, such as respiratory rate or cardiac output, have profound effects on exhaled VOCs, here we investigated VOC exhalation under respiratory manoeuvres. Breath VOCs were monitored by means of real-time mass-spectrometry during conventional FEV manoeuvres in 50 healthy humans. Simultaneously, we measured respiratory and hemodynamic parameters noninvasively. Tidal volume and minute ventilation increased by 292 and 171% during the manoeuvre. FEV manoeuvre induced substance specific changes in VOC concentrations. pET-CO2 and alveolar isoprene increased by 6 and 21% during maximum exhalation. Then they decreased by 18 and 37% at forced expiration mirroring cardiac output. Acetone concentrations rose by 4.5% despite increasing minute ventilation. Blood-borne furan and dimethyl-sulphide mimicked isoprene profile. Exogenous acetonitrile, sulphides, and most aliphatic and aromatic VOCs changed minimally. Reliable breath tests must avoid forced breathing. As isoprene exhalations mirrored FEV performances, endogenous VOCs might assure quality of lung function tests. Analysis of exhaled VOC concentrations can provide additional information on physiology of respiration and gas exchange.


Breath analysis is an evolving interdisciplinary science that involves physiology and medicine with analytical chemistry and engineering. It holds promise towards noninvasive clinical diagnosis as well as therapeutic and physiological monitoring1,2,3,4,5,6,7,8,9,10. In early years, researchers were mainly focused on the discovery of trace (~ppbV to ~pptV ranges) gases in human breath as unique biomarkers for diseases. Despite the identification of more than 300 volatile organic compounds (VOCs) in exhaled breath during the last decade, not a single substance could be established as disease specific biomarker for clinical use. This was not only a consequence of inadequate fundamental knowledge on the origin, distribution and exhalation kinetics of individual markers but also due to insufficient understanding of complex physiological effects on breath VOC concentrations.

Pulmonary ventilation and perfusion are physiological determinants, which influence the alveolar gas exchange and thereby, VOC exhalation. Simple changes in physiology may have sudden and profound effects on breath VOC concentrations, which often override the actual pathophysiological effects. Recent studies have clearly demonstrated that hemodynamic changes induced by different breathing patterns or postures have immediate substance specific effects on VOC exhalation11,12. In addition, confounders such as environmental, dietary or oral/nasal cavity exposure and clinical contaminations are equally important as pathophysiological conditions or biological pathways11,12,13.

Recent development and application of advanced real-time mass-spectrometric (MS) techniques such as selected ion flow-tube (SIFT)-MS, proton transfer reaction (PTR)-Quadrupol-MS and PTR-Time of flight (ToF)-MS along with online end-tidal/alveolar sampling have substantially reduced several confounding variables associated with sample storage, analysis time and mixed breath matrix14,15,16,17,18. Such improvements in sampling, analysis and statistical validation have led to the indication that concentration changes are more important than unique breath biomarkers11,12,13. At present, online monitoring of instant physiological changes in exhaled VOC profiles is possible with the required analytical sensitivity or resolution, which also enables clinicians to relate different biochemical and metabolic processes to exhaled VOCs2,8,9,14,15,16,17,18.

We realized that the origin, physico-chemical characters and mostly alveolar gas exchange and compartmental distribution, are accountable for clinical interpretations of exhaled substances as breath biomarker11,12. Thus, the combined effect of the most influential physiological aspects such as hemodynamics and ventilation has to be investigated in extensive detail. We designed a study to investigate the effect of forced expiratory volume (FEV) manoeuvre onto the compositions of exhaled breath. Here, we applied real-time mass-spectrometry on healthy human subjects for breath resolved measurement of exhaled volatiles in parallel to continuous spirometry, side-stream capnometry and noninvasive monitoring of hemodynamic parameters. The following questions were addressed in detail:

  • Is there any immediate physiological effect of FEV manoeuvre on VOC exhalation?

  • Are those effects substance specific?

  • Do such effects depend on ventilation and hemodynamic parameters?

  • Can these changes be used to monitor lung functions or hemodynamic parameters?

Results

Heat maps (Fig. 1) represent an overview of relative changes for selected marker substances and respiratory parameters over the course of the entire experiment. These 18 VOCs were chosen because they had significantly higher concentration in expired air than in inspired air. Profound changes of exhaled VOC concentrations were induced within seconds, when respiratory and hemodynamic parameters changed during and after the FEV manoeuvre. Inspiratory concentrations remained constant during the experiment. Detailed data on relative changes (in %), normalized mean values and variations of different VOC concentrations, respiratory and hemodynamic parameters are listed in Table 1 and Supplementary Table 1.

Figure 1. Relative changes in normalized alveolar concentrations of 18 selected compounds and respiratory parameters from 50 healthy volunteers.

Figure 1

A schematic spirogram profile of exhaled breaths is presented on the top of the figure. Protonated compounds were tentatively identified based on their m/z ratio. VOC concentrations and respiratory parameters were normalized onto values in the third exhalation (‘N’). The beginning and the end of the second minute is represented by two vertical black lines. FEV manoeuvre was performed at the beginning of 2nd minute. During the manoeuvre the maximum exhalation point is marked as ‘M’ and the forced expiration point is marked as ‘F’. VTex = expiratory tidal volume, pET-CO2 = end-tidal partial pressure of carbon dioxide, VE = minute ventilation and FIO2 = fraction of inspiratory oxygen.

Table 1. Changes in normalized concentrations of six different VOCs and changes (A,B) in normalized values of respiratory (A) and hemodynamic parameters (B).

A
 Protonated VOCs Mass [gm mol−1] Minute Breath (%)Change of normalized mean values Significance/Breath (P-value) Respiratory parameters Minute Breath (%)Change of normalized mean values Significance/Breath (P-value)
Comparison point 1st 4th 0 N/A Comparison point 1st 4th 0 N/A
(Isoprene)H+69.06989 1st 8th 6.08 <0.001 Expiratory tidal volume [L] 1st 8th −8.57 0.070
1st 12th 11.12 0.001 1st 12th −8.03 0.175
2nd Max 21.18 <0.001 2nd Max 106.28 <0.001
2nd Forced −18.41 <0.001 2nd Forced 291.66 <0.001
2nd 4th −37.26 <0.001 2nd 4th 164.99 <0.001
2nd 8th 21.16 <0.001 2nd 8th 7.30 <0.001
3rd 1st 12.33 <0.001 3rd 1st −0.11 0.020
3rd 5th 1.62 0.668 3rd 5th −4.67 0.063
3rd 9th −5.03 <0.001 3rd 9th −7.57 0.004
Comparison point 1st 4th 0 N/A Comparison point 1st 4th 0 N/A
(C2H6S)H+ 63.0263 1st 8th 1.31 0.914 Minute ventilation [L/min] 1st 8th −5.74 0.020
1st 12th 1.68 0.668 1st 12th −6.91 0.282
2nd Max 6.99 <0.001 2nd Max 41.36 <0.001
2nd Forced −5.79 <0.001 2nd Forced 171.40 <0.001
2nd 4th −12.75 <0.001 2nd 4th 145.77 <0.001
2nd 8th 4.96 <0.001 2nd 8th 11.16 <0.001
3rd 1st 3.90 <0.001 3rd 1st −0.19 0.154
3rd 5th −1.50 <0.001 3rd 5th −3.57 0.336
3rd 9th −2.33 <0.001 3rd 9th −7.10 0.008
Comparison point 1st 4th 0 N/A Comparison point 1st 4th 0 N/A
(Acetone)H+ 59.04914 1st 8th −0.27 <0.001 pET− CO2 [kPa] 1st 8th −0.73 0.203
1st 12th 0.25 0.086 1st 12th −2.41 <0.001
2nd Max 0.02 0.238 2nd Max 6.08 <0.001
2nd Forced 4.45 <0.001 2nd Forced −18.28 <0.001
2nd 4th 1.41 <0.001 2nd 4th −24.80 <0.001
2nd 8th 1.32 0.001 2nd 8th −7.91 <0.001
3rd 1st 1.11 0.009 3rd 1st −9.20 <0.001
3rd 5th 0.54 0.053 3rd 5th −10.82 <0.001
3rd 9th 0.76 0.418 3rd 9th −11.53 <0.001
B
Protonated VOCs Mass [gm mol−1] Minute Breath (%) Change of normalized mean values Significance/Breath (P-value) Hemodynamic parameters Minute Time [s] (%)Change of normalized mean values Significance/Time (P-value)
Comparison point 1st 4th 0 N/A Comparison point 1st 40th s 0 N/A
(Acetonitrile)H+42.03382 1st 8th −3.34 0.125 Stroke volume [ml/beat]        
1st 12th −2.16 0.001 1st 60s −0.27 0.819
2nd Max 1.71 <0.001 2nd 20s −14.17 <0.001
2nd Forced −0.26 0.001 2nd 40s 3.74 <0.001
2nd 4th −4.73 0.257 2nd 60s 2.12 <0.001
2nd 8th −2.46 0.048 3rd 20s −1.04 0.014
3rd 1st −2.94 0.005 3rd 40s −1.43 0.003
3rd 5th −4.94 0.008 3rd 60s −2.39 <0.001
  3rd 9th −5.64 0.007          
Comparison point 1st 4th 0 N/A Comparison point 1st 40th s 0 N/A
(Furan)H+ 69.03349 1st 8th 7.11 <0.001 Cardiac output [L/min]        
1st 12th 3.43 0.001 1st 60s 0.14 <0.001
2nd Max 11.83 <0.001 2nd 20s −6.45 <0.001
2nd Forced −16.27 <0.001 2nd 40s 14.49 <0.001
2nd 4th −32.20 <0.001 2nd 60s 1.80 0.001
2nd 8th 13.43 <0.001 3rd 20s −1.22 0.120
3rd 1st 4.68 <0.001 3rd 40s −0.99 0.040
3rd 5th −3.25 <0.001 3rd 60s −1.58 0.127
  3rd 9th −5.43 <0.001          
Comparison point 1st 4th 0 N/A Comparison point 1st 40th s 0 N/A
(C4H8S)H+ 89.04195 1st 8th −1.38 1.000 Pulse rate [beats/min]        
1st 12th −1.59 0.253 1st 60s 0.21 0.794
2nd Max 0.09 0.002 2nd 20s 12.04 <0.001
2nd Forced −11.61 <0.001 2nd 40s 10.70 <0.001
2nd 4th −10.40 <0.001 2nd 60s −0.74 0.018
2nd 8th −2.92 0.005 3rd 20s −0.40 0.819
3rd 1st −3.64 0.039 3rd 40s 0.40 0.038
3rd 5th −8.14 <0.001 3rd 60s 0.88 0.006
  3rd 9th −8.12 <0.001          

VOC concentrations from every forth exhalation as well as from the maximum and forced expiration of the second minute were compared to the 4th breath of the first minute. Respiratory parameters were compared in the same way. (%) Change of normalized mean values: Positive values represent an increase and negative values represent a decrease. Significance/Breath: differences between the reference value and actual values were assessed by means of repeated measurement-ANOVA on ranks. Hemodynamic parameters were compared with the 40th s of the first minute. Significance/Time: differences between the reference value and actual values were assessed by means of repeated measurement-ANOVA on ranks.

Changes in exhaled VOC concentrations

All relative changes (in %) in VOC concentrations refer to the 4th exhalation from the 1st min (Supplementary Fig. S1). Normalized mean alveolar concentrations (normalized onto 3rd exhalation) of isoprene, furan and dimethyl-sulphide (C2H6S) increased by 21%, 12% and 7%, respectively during maximum exhalation (on 70th s before the forced expiration) and decreased by 18%, 16% and 6% at forced expiration (on 77th s). They decreased further by 37%, 32% and 13%, respectively, just after Forcedout (on 84th s). Concentrations of these compounds then increased again by 21%, 13% and 5% and even exceeded baseline levels (Fig. 2 A) on 113th s following the time profiles of stroke volume, cardiac output and pET-CO2 (Table 1). Less pronounced changes were observed for concentrations of acetonitrile, allyl-methyl-sulphide (C4H8S) and isopropanol (C3H8O). In this setup, acetone concentrations increased by 4.5% at Forcedout (Fig. 2B). In contrast, concentrations of other compounds such as hydrogen sulphide (H2S), ammonia (NH3), formaldehyde (CH2O), methanol (CH4O), butane (C4H8), benzene (C6H6) and toluene (C7H8) etc. remained almost constant (Fig. 1).

Figure 2. Time profiles of normalized exhaled alveolar substance concentrations, respiratory and hemodynamic parameters from 50 healthy volunteers.

Figure 2

Diagram (A) represents the changes for hemodynamic [Cardiac Output, Stroke Volume and Pulse Rate] parameters (on top), VOC [Isoprene, Furan and C2H6S] concentrations (in middle) and respiratory [VTex and VE] parameters (at bottom). Diagram (B) shows changes for VE in primary Y axis and that of Cardiac Output in secondary Y axis (on top), VOC [Acetonitrile and C4H8S] concentrations (middle) and pET-CO2 and Acetone (bottom). The vertical black lines at 60th and 120th second represent the beginning and end of the second minute. The data points for normalization are indicated as ‘N’. “M” and “F” represent the end of Maxout and Forcedout, respectively. Coloured error bars represent standard deviations. A schematic spirogram profile of exhaled breaths is presented on the top of each diagram.

Changes in respiratory parameters

All relative changes (in %) in respiratory parameters refer to the 4th exhalation from the 1st min (Supplementary Fig. S1). Normalized mean values (normalized onto 3rd exhalation) of expiratory tidal volume and minute ventilation increased by 106 and 41%, respectively during maximum exhalation (on 70th s) and increased by 292 and 171% at forced expiration (on 77th s). They came back to base line on 94th second (Fig. 2A). In contrast, pET-CO2 increased by 6% at maximum exhalation, decreased by 18% at forced expiration. After that it decreased further by 25% in the next breath. From the second breath after Forcedout, pET-CO2 increased again, up to 10% below the base line and then remained constant at that level (Fig. 2B). FIO2 remained constant throughout the experiment. V′O2 and V′CO2 were increased substantially by 29% and 88% at Forcedout (Fig. 1).

Changes in hemodynamic parameters

All relative changes (in %) in hemodynamic parameters refer to the 40th s time point from the 1st min (Supplementary Fig. S1). Normalized mean values of stroke volume and cardiac output decreased by 14 and 6%, respectively during forced expiration, and increased by 4 and 14% in following 20 s. In contrast, pulse rate increased by 10% during FEV manoeuvre and decreased by 1% within the next 20 s (Fig. 2A). All hemodynamic values returned to base level during the first 20 s of the third minute.

Detailed statistical comparisons of differences between breaths in relation to exhaled VOC concentrations and respiratory parameters and similar comparisons for hemodynamics parameters for consecutive measurement points are shown in Table 1.

Isoprene exhalation model for monitoring of FEV maneuvers

The percentage of decrease in isoprene concentrations from Forcedout to following normal expiration are closely related to the percentage of FEV1 performances. The polynomial regression models (Fig. 3) predicting percentage of performed FEV1 from the decrease in isoprene concentrations are as follows:

  • 1storder polynomial regression equation
    graphic file with name srep28029-m1.jpg
  • 2nd order polynomial regression equation

graphic file with name srep28029-m2.jpg

Figure 3. Polynomial regression models for percentages of decrease in alveolar isoprene concentration and percentages of FEV1 performance.

Figure 3

The percentages of performed FEV1 are plotted in X-axis, Y-axis represents relative decrease in isoprene concentration. Two orders of regression equations along with the respective R2 values are presented. Isoprene decreased as the function of FEV1 performance, which is illustrated with a negative slope. Red lines are regressions lines of 1st and 2nd order.

The overall results of different orders of regression are also presented in Table 2. As the third order of regression did not improve the R2 value significantly, it was excluded from the model.

Table 2. Overall results of polynomial regressions.

Order R2 F-test P-value
1st 0.797 86.477 <0.001
2nd 0.855 62.032 <0.001
3rd 0.856 39.504 <0.001

The strengths of correlations between models and response variables are represented as R2 values. F-test simultaneously accesses multiple coefficients of regression and compares the fits of different linear models. The P-values stand for the statistical significance of corresponding F-test.

Discussion

In 50 volunteers we observed pronounced and immediate effects of forced respiratory maneuvers on exhaled VOC concentrations. FEV manoeuvre induced changes in both ventilation and hemodynamics, which subsequently changed VOC profiles. Correlations between concentrations of volatile substances e.g. isoprene, furan, and C2H6S and cardiac output, tidal volume, minute ventilation and pET-CO2 were observed. Comparatively less prominent effects were visible for C4H8S and acetonitrile. In contrast, compounds such as H2S, benzene, and toluene were almost unaffected by FEV manoeuvre induced physiological changes. FEV manoeuvre induced changes in VOC concentrations normalized to base line when respiratory and hemodynamic parameters went back to pre-FEV levels.

When subjects performed the FEV manoeuvre in a sitting position, they produced an extensive intrathoracic pressure, which significantly lowered venous return and ventricular preload. Eventually, according to the Frank-Starling Mechanism19,20 stroke volume and cardiac output also decreased. Due to a baroreceptor mediated increase in pulse rate21,22, cardiac output decreased moderately less than stroke volume during forced expiration. As tidal volume and minute ventilation increased during forced respiration exhaled VOCs could be expected to be diluted during these phases.

During FEV manoeuvre, all participants tried to exceed their maximal expiratory flow (MEF) rate and contracted their abdominal and intrathoracic muscles and diaphragm. As MEF depends on individual lung volume, intraluminal pressure falls rapidly from alveoli towards mouth during the effort of forced expiration. This dynamically collapsed the bronchioles, below the equal pressure point (i.e. Pintraluminal = Ptransthoracic) and MEF remained limited through intrathoracic airway resistance23. This may cause intrapulmonary shunt (lung areas, which are not ventilated but perfused)24,25,26.

Statistically significant differences of substance concentrations occurring within the study period can be attributed to the FEV manoeuvre induced changes in hemodynamic and respiratory parameters. CO2 exhalation normally depends on cardiac output, minute ventilation and the extent of dead space ventilation. As spontaneously breathing volunteers may hyperventilate due to paced breathing, pET-CO2 tended to decrease gradually during the last 25 s before the manoeuvre. During the FEV manoeuvre, pET-CO2 only partially followed the time profile that would have been predicted from stroke volume and cardiac output. This is mostly due to factors such as expiratory time, mean alveolar partial pressure of CO2 (PCO2) and alveolar slope27,28 becoming determinants for pET-CO2 under the conditions of forced respiration. At maximum exhalation (Maxout) pET-CO2 increased significantly when stroke volume and cardiac output had already started to decrease. This increase is attributed to a change of alveolar slope during longer expiratory time, as alveolar blood-breath contact time for gas exchange was prolonged in order to empty additional lung volume (i.e. ERV). After Maxout, pET-CO2 started to decrease pronouncedly during the maximum inhalation (Maxin) and did not increase at forced expiration (Forcedout) because of dilution during Maxin and due to the significant decrease in cardiac output29. After Forcedout, once the participants did forced inspiration (Forcedin) a further dilution of CO2 took place, which was reflected during the next normal exhalation. Although cardiac output already started to rise instantly after Forcedout, due to the elevated pulse rate and stroke volume, pET-CO2 only increased from the second breath after the manoeuvre onwards. This was due to the relative hyperventilation going on until tidal volume and minute ventilation came back to baseline at the second breath after the manoeuvre. I.e. in this phase effects of cardiac output onto pCO2 were partially overridden by relative hyperventilation and consecutive dead space ventilation30,31.

Acetone originates from lipolysis and glycolysis32. In our previous study, normalized mean alveolar concentrations of acetone remained almost constant during changes in postures. No effect of hemodynamic changes was observed on acetone, mainly due to its miscibility in water, high volatility, relatively large amount of production and higher rate of distribution within lung compartments12. From theory, especially from multiple inert gas elimination technique (MIGET)33,34 one would expect that acetone being a highly soluble compound should behave similarly to CO2. However, in contrast to pCO2, there was a small (~4.5%) but significant (P < 0.001) increase in alveolar acetone concentrations at forced expiration. A possible explanation could be, that under the special conditions of forced expiration exchange phenomena from bronchial epithelium contributed to the exhaled concentrations of acetone35,36. Recent studies have also suggested partial exchange of VOCs with good water solubility and relatively higher blood:air partition coefficient within the bronchial tree in certain conditions such as increased bronchial perfusion or elevated exhalation flow36,37,38. Thus the unusual behaviour of acetone at Forcedout could be related to its extra-alveolar exchange within the airways. It might additionally be facilitated primarily by a pre-alveolar absorption during Maxin and afterwards by a post-alveolar revaporization during Forcedout due to the rapidly decelerating flow of forced expiration17.

Isoprene originates mainly from cholesterol biosynthesis39. Isoprene exhalation normally is positively correlated with cardiac output and negatively correlated with ventilation12. The increase in isoprene concentrations from first 30 s onwards is in accordance with the consecutive small increase in cardiac output and the simultaneous decrease in minute ventilation. From Maxout till next normal exhalation isoprene exactly followed the time profile of pET-CO2. Similar to CO2, isoprene exhalation during the FEV manoeuvre must have been influenced by factors other than cardiac output and ventilation. Due to its very low aqueous solubility (0.009 mol/L at 20 °C)12, alveolar concentrations of isoprene probably mirrored the pulmonary ventilation-perfusion effect during and after the manoeuvre. From the second normal exhalation after FEV manoeuvre, isoprene represented a perfusion driven increase during the following 15 s and then gradually decreased mirroring the cardiac output profile.

Other blood-borne compounds such as furan and C2H6S, which are related to smoking habits and bacterial emissions, respectively, also followed the exhalation pattern of isoprene due to their comparable solubility. Comparatively less pronounced changes were observed for compounds like acetonitrile and C4H8S, which originate from smoking/environment and dietary intakes, respectively40. Due to having a relatively higher aqueous solubility these two compounds did not exactly follow the behaviour of isoprene. On the other hand, H2S being produced mainly from oral cavity bacteria11,12, remained almost unaffected. There was a minor decrease in exhaled H2S concentrations during forced expiration, which could be attributed to its dilution due to higher tidal volume at that moment. Benzene and toluene are two blood borne and lipophilic compounds, which accumulate mainly from environmental exposure40. Due to their high rate of distribution in fatty compartments alveolar profiles of both compounds remained almost constant. Although participants were most probably not exposed to environmental compounds all in the same way, benzene, toluene, furan and acetonitrile were detectable in all 50 subjects. This is due to the variable but ubiquitous exposure to benzene and toluene and to active and passive smoking in the case of furan and acetonitrile.

Inter-individual variations are inevitable in every in vivo study. As our study involved only 50 volunteers, we did not try to relate any demographic parameters such as age, sex or BMI to such variations. To reduce these variations, we normalized all VOC concentrations and respiratory parameters onto their corresponding values in the third breath of the measurement cycle. Similarly, hemodynamic parameters were normalized onto values from first 40th s. 10–15 breaths/min is regarded as normal breathing in healthy human adults. In order to reduce additional variations in ventilation, all participants were asked to maintain a respiratory rate of 12/min by following a metronome sound.

Execution of a correct FEV manoeuvre mainly depends on the understanding of physician’s instructions by the subject. In addition, there are several manual biases involved with both performance and analysis of such respiratory maneuvers41,42,43 As these pulmonary function tests are mandatory for the diagnosis of obstructive44 and restrictive45,46,47 lung conditions, it is extremely important to have a reliable and unbiased quality assurance of such test. As participants of this study did not suffer from COPD or asthma, deviations from normal FEV1 range and Tiffeneau Score could be attributed to low performance in doing the test. Therefore, in each participant, deviations of actual FEV1 and Tiffeneau score (FEV1/FVC ratio) from expected values (predicted from the age, gender and BMI based population studies) was rated as percentage of performance. A second order polynomial regression equation (2) turned out to reliably predict the percentage of FEV1 performance from the decrease in isoprene concentrations. In a perspective, exhaled concentrations of low-solubility substances such as isoprene might be used for quality control of Tiffeneau testing. This could be especially beneficial for lung function tests in sports medicine and physical fitness tests in healthy subjects and athletes.

As exhaled substance concentrations markedly depend on physiological parameters, such as breathing patterns, flow and airway resistances, unforeseeable and highly variable effects onto results have to be expected when any forced and non-physiological breathing maneuvers are used during breath sampling. Results of this study demonstrate that knowledge from pulmonary and airway gas exchange theory has to be taken into account when breath sampling is to be done in a reliable way. Analysis of exhaled VOC concentrations can provide additional information on physiology of respiration and gas exchange. Our results underline the importance of control and standardization of breath sampling with respect to tidal volume, respiratory rate, flow and airway resistance. In a perspective, breath VOCs could be used for quality assurance of lung function tests.

Methods and Materials

All experiments were carried out in accordance with Declaration of Helsinki guidelines. All experimental protocols were approved (Approval number: A 2015-0008) by the Institutional Ethics Committee (University Medical Centre Rostock, Rostock, Germany) and signed informed consents from all subjects were obtained before conducting measurements.

Experimental setup

We combined three devices, for real-time measurements of several parameters in parallel (Fig. 4A).

  • PTR-ToF-MS for continuous monitoring (time resolution: 200 ms) of breath VOC concentrations.

  • Flow-volume spirometry and side-stream capnometry for breath-resolved measurement of lung function (e.g. respiratory rate, tidal volume, minute ventilation) and pET-CO2.

  • Volume clamp method for non-invasive determination of hemodynamics (e.g. blood pressure, cardiac output, pulse rate).

Figure 4.

Figure 4

Experimental setup [A] and the measurement protocol [B] of the study. [A] Parallel monitoring of breath VOCs by PTR-TOF-MS (1), lung function parameters and pET-CO2 by means of spirometry and capnometry (2) and hemodynamic parameters such as SV = stroke volume, CO = cardiac output, PR = pulse rate and MAP = mean arterial pressure (3). [B] Schematic spirogram of the whole experiment during tidal breathing and FEV manoeuvre. Spirogram of FEV manoeuver: VC = vital capacity, VT = tidal volume, ERV = expiratory reserve volume, IRV = inspiratory reserve volume, IC = inspiratory capacity, RV = residual volume and TLC = total lung capacity.

All devices were synchronised, and data acquisition was initiated simultaneously.

Measurement protocol for healthy volunteers

Demographic data from 50 healthy participants (27 males, 23 females; aged between 21–54 years) are shown in Table 3. In order to explain and prepare the test procedures, volunteers were requested to appear at least 30 min before the actual measurements. Participants were asked to breathe normally (Respiratory rate = 12/minute) through a sterile mouthpiece following a metronome sound to determine normal tidal volume (VT). After 13 normal breaths, volunteers performed the forced expiratory volume (FEV) manoeuvre and then again breathed normally until the end of the third minute (Fig. 4B).

Table 3. Demographic data of healthy volunteers.

ID Age (years) Sex Height [cm] Weight [kg] Smoker BMI ID Age (years) Sex Height [cm] Weight [kg] Smoker BMI
1 30 M 168 64 No 23 26 32 M 172 69 No 23
2 32 M 184 72 No 21 27 29 F 169 78 Yes 27
3 29 M 186 80 No 23 28 32 M 166 65 No 24
4 26 M 183 72 No 22 29 29 M 166 62 No 22
5 28 M 168 72 No 26 30 28 F 173 68 No 23
6 26 F 165 72 No 26 31 33 F 170 68 No 24
7 29 M 177 70 Yes 22 32 28 F 170 66 No 23
8 28 M 193 85 No 23 33 25 M 167 65 No 23
9 26 F 170 63 No 22 34 31 M 171 68 No 23
10 25 F 162 50 No 19 35 28 F 167 62 No 22
11 28 F 171 90 No 30 36 27 M 162 79 No 30
12 46 M 186 75 No 22 37 25 F 158 49 No 20
13 47 M 195 103 No 27 38 23 M 185 65 No 19
14 22 F 170 66 No 23 39 34 M 180 90 No 28
15 31 M 162 63 No 24 40 24 F 172 65 No 22
16 31 M 169 70 No 24 41 29 M 164 67 No 25
17 26 F 181 68 No 21 42 24 M 163 62 No 23
18 43 F 168 60 Yes 21 43 30 M 190 91 Yes 25
19 54 M 189 106 No 30 44 29 F 169 65 No 23
20 34 M 172 75 No 25 45 31 F 172 71 No 24
21 20 M 188 83 No 24 46 22 F 178 70 No 22
22 26 M 169 68 No 24 47 27 F 170 68 Yes 24
23 31 F 172 68 No 23 48 46 F 165 62 No 23
24 23 F 168 68 No 24 49 27 F 168 70 Yes 25
25 21 F 180 68 No 21 50 32 M 170 67 No 23

Data regarding participants’ age, sex, height, body weight, smoking habit and body mass index (BMI) are presented.

The FEV manoeuvre consists of 4 distinct steps:

  • a maximum exhalation (Maxout): Exhalation of tidal volume (VT) and expiratory reserve volume (ERV)

  • a maximum inhalation (Maxin): Inhalation of the vital capacity (VC) corresponding to tidal volume (VT), expired (ERV) and inspired (IRV) reserve volumes,

  • followed by a forced expiration (Forcedout) to exhale the vital capacity (VC) as fast as possible

  • and finally a forced inspiration (Forcedout) to inhale the vital capacity corresponding to tidal volume (VT), expiratory (ERV) and inspiratory (IRV) reserve volumes as fast as possible (spirogram in Fig. 4 B).

Nose clips were used to prevent any partial nasal exhalation during the measurements. According to ERS guidelines, we repeated the entire measurement cycle (3 min) in all volunteers to check any possible differences in the performance and execution of the FEV manoeuvre. As we did not find any significant differences between these measurements, the first test of each participant was used for statistical evaluation.

PTR-ToF-MS for breath VOCs analysis

Instrumentation

We used an online PTR-ToF-MS-8000 (Ionicon Analytik GmbH, Innsbruck, Austria) for continuous real-time measurement of volatile organic compounds (VOCs) in breath. The working principle and conditions of the instrument for breath sampling were described in several studies11,12. Concisely, the soft ionisation of VOCs is based on a non-dissociative proton transfer reaction [VOC + H3O+ → (VOC)H+ + H2O], which ionises VOCs with relatively higher proton affinity than water. Protonated VOCs are then detected in a high resolution reflectron time-of-flight mass spectrometer (Tofwerk AG, Thun, Switzerland) according to their mass to charge (m/q) ratio. There is no requirement for preconcentration and ambient air can be used as buffer gas. We sampled breath in a continuous side-stream mode by using a 6 m long inert and heated silco-steel transfer-line (ID 0.75 mm, Restek, Bellafonte, USA), which was connected to the sterile mouthpiece. Table 4 shows, PTR-ToF-MS-8000 measurement parameters.

Table 4. PTR-ToF-MS-8000 measurement parameters for our study.
Transfer line Ion source PTR drift tube ToF-MS
Inlet Flow Temp. Inlet Flow Current E/N Ratio Temp. Pressure Voltage Mass resolution
20 sccm 75 °C 6–7 sccm 4–5 mA 137–139 Td 75 °C 2.3 mbar 610 V 4000–5000 FWHM

Optimised operating values for transfer line, ion source, PTR drift tube and time of flight-mass spectrometry (ToF-MS) are presented.

A time resolution of 200 ms for data acquisition was realized by the associated ToF-DAQ Software. After every minute of measurement, a file was automatically recorded and the mass scale was calibrated by using the following masses: H3O+-isotope: 21.0226 Th; NO+: 29.9980 Th; protonated acetone: 59.049 Th.

Data processing

All VOCs were measured in counts per seconds (cps) and their intensities were normalised onto primary ion (H3O+) counts. We used a custom-made data processing algorithm called ‘breath tracker’ (MATLAB version 7.12.0.635, R2011a) to identify alveolar and inspiratory phases of breath11,12. Any endogenous and blood-borne compound that has relatively higher signal intensity in expiration can be used as a tracker mass. In our study, acetone was used as the tracker mass.

Spirometry and capnometry for measurements of respiratory parameters

We conducted breath-resolved spirometry and side-stream capnometry by using the Oxycon Mobile device (CareFusion GmbH, Hoechberg, Germany). Subsequent data analysis was performed by the JLAB Software 5.3x (Version 02.00). This equipment complies with all criteria of both European Respiratory Society (ERS) and American Thoracic Society (ATS) standards and has been validated for clinical and laboratory practice48,49.

The main device consists of a flow-volume sensor (TripleV unit), a gas sensor box (SBx/CPX unit), a data exchange unit (DEx transmitter) and a power calibration unit (PCa receiver). An ambient unit and a gas analyser are integrated in the SBx unit, which determine the ambient conditions and O2/CO2 content in calibration gas (Standard content: 5% CO2 and 16% O2), respectively. The TripleV unit comprises of a rotatory flow sensor, a main-stream volume sensor (electrical infrared) and a sample tube, connected to the side-stream capnometer (integrated in SBx unit). The TripleV-SBx unit allows continuous breath-by-breath and intra-breath measurements of spirometric (lung functions) and capnometric (pET-CO2) values in real-time. The DEx is used for recording, storage and telemetric transfer of data to the PCa unit. The PCa unit receives telemetric data as a PC-interface to the JLAB Software and is also used actively during calibrations. Prior to inclusion of every new participant, measurement of the ambient conditions as well as volume and gas calibrations were performed. General respiratory parameters such as respiratory rate, tidal volume, minute ventilation, FIO2 and pET-CO2 etc. were recorded breath-by breath. The FEV manoeuvre was performed during an intra-breath phase and additional lung functions such as FEV1 (forced expiratory volume in 1st s), FVC (forced vital capacity) and EELV (end expiratory lung volume) etc. were recorded for subsequent time points. Additional metabolic parameters such as RER, V′O2, V′CO2 were assessed by this system. These values usually are determined during stable conditions of rest or exercise50,51. As these values are calculated from spirometric data, the sudden and exceptional manoeuvre our volunteers were told to do induced artificial variations which, therefore, do not mirror any real change of these metabolic parameters.

Volume clamp method for non-invasive monitoring of hemodynamics

Any invasive approach for hemodynamic monitoring in healthy volunteers is not possible for ethically reasons. Thus, we used a ClearSight System EV1000 (Edwards Lifesciences, California, USA) for continuous, non-invasive measurement of hemodynamic parameters in real-time. The instrument and associated volume clamp method are described in previous study12. Briefly, a suitable finger-cuff is used for each participant to clamp the middle phalanges of either index or middle finger. A heart reference sensor calibrates the relative position of the finger-cuff with respect to the heart. The finger-cuff (with infrared sensing technology) and the pressure controller measure blood pressure variations over time, which results in a photo-plethysmogram. The initial blood pressure waveform and associated parameters are recorded approximately in first 20 s. Blood pressure, pulse rate, stroke volume and cardiac output are recorded and calculated in 20 s intervals from the arterial waveform, which is derived from the photo-plethysmogram and pressure waveform. Although the standard errors for absolute values in this system range between 20% in healthy subjects, relative changes in all parameters are tracked with acceptable accuracy12,52.

Statistical analysis

Comparison of differences

Every fourth breath along with the maximum and forced exhalation (from the 2nd min) was included for statistical comparisons for VOC concentrations and respiratory parameters. We excluded the hemodynamic data from the first 20 s of the measurement cycle to avoid any possible artefact from the arterial waveform calibration time of the ClearSight System. Thus every data point for hemodynamic parameters was compared to the 40th s time point from the first minute.

Statistically significant differences between VOC concentrations, respiratory and hemodynamic parameters were determined by means of repeated measurement ANOVA on ranks (Friedman repeated measures analysis of variance on ranks, Shapiro-Wilk test for normal distribution and post hoc Student–Newman–Keuls method for pairwise multiple comparisons between all groups; P-value < 0.05) using SigmaPlot (version 13). From all pairwise comparisons, we selected those referring to the 4th breath and 40th s of the 1st min. For a minimum detectable difference in mean substance intensities of 400 cps and an estimated standard deviation of 400, 10 groups, each group size of 50 and alpha = 0.05 the power of the test was 0.959. A schematic overview of the statistical comparisons is presented in Supplementary Fig. S1.

Correlation analysis

In order to investigate correlations between the behaviour of VOC concentrations and the respiratory and hemodynamic parameters during and after the manoeuvre, we applied polynomial regression analysis (SigmaPlot; version 13).

Modelling of VOC exhalations to monitor FEV performances

FEV is a standard respiratory manoeuvre, which is discussed in the measurement protocol. Each manoeuvre consists of two exhalations; a maximum exhalation (Maxout) followed by a forced expiration (Forcedout). In order to model some VOCs of interest during and after the manoeuvre those two exhalations and the very next normal exhalation were used for modelling. As the volume of Maxoutremained very reproducible in any individual, we reduced inter-individual variations in our analysis by normalizing the absolute VOC concentrations in both Forcedout and the following normal exhalation onto the Maxout point for each participant. Forced vital capacity (FVC) is the total volume of Forcedout after a Maxin and FEV1 is the volume exhaled within the 1st s of forced expiration. FEV1/FVC ratio (Tiffeneau-Pinelli index) is an important parameter in lung function testing within the field of pulmonology and respiratory medicine. Performance of FEV1 and analysis of Tiffeneau score lies on considerable manual biases. In order to establish an unbiased quality control of such test, we investigated the dependency of VOC exhalations on the maneuvers. Thus, we compared the relative changes in substance concentrations with the percentage of individual FEV1 performances (performed % of the predicted value from age, sex and BMI based population studies) by means of polynomial regression (SigmaPlot; version 13).

Additional Information

How to cite this article: Sukul, P. et al. FEV manoeuvre induced changes in breath VOC compositions: an unconventional view on lung function tests. Sci. Rep. 6, 28029; doi: 10.1038/srep28029 (2016).

Supplementary Material

Supplementary Information
srep28029-s1.pdf (282.4KB, pdf)

Acknowledgments

We thank all the volunteers and the entire ROMBAT Group for participating and supporting this study. Special thanks to Mr. Andreas Prestel (Master toolmaker at Oscar Langendorff Institute of Physiology, 2 University Medicine Rostock, Germany) for customizing the mouth pieces, which were used in this study. The PTR-ToF-MS instrument used in this study was entirely funded by the European fund for regional development (EFRE). This study was financially supported by Marie Curie EU Grant (FP7-PEOPLE-ITN-PIMMS project, grant agreement no. 287382) and EU grant H2020 (H2020-PCH-HEARTEN project, grant agreement no. 643694).

Footnotes

Author Contributions P.S. developed the idea, designed the study, recruited volunteers, performed experiments, analysed and interpreted results and wrote the manuscript. J.K.S. contributed in conception, clinical interpretation and discussion. P.O. supported measurements and data analysis. S.K. helped in instrumentation, clinical interpretation and discussion. K.T. helped in measurements and inclusion of volunteers. P.T. supported measurements and proof reading. W.M. contributed in study design and proof reading. All authors reviewed the manuscript and contributed in writing.

References

  1. Miekisch W., Schubert J. K. & Noeldge-Schomburg G. F. E. Diagnostic potential of breath analysis–focus on volatile organic compounds. Clin. Chim. Acta Int. J. Clin. Chem. 347, 25–39 (2004). [DOI] [PubMed] [Google Scholar]
  2. Herbig J. et al. On-line breath analysis with PTR-TOF. J. Breath Res . 3, 027004 (2009). [DOI] [PubMed] [Google Scholar]
  3. Miekisch W., Fuchs P., Kamysek S., Neumann C. & Schubert J. K. Assessment of propofol concentrations in human breath and blood by means of HS-SPME-GC-MS. Clin. Chim. Acta Int. J. Clin. Chem. 395, 32–37 (2008). [DOI] [PubMed] [Google Scholar]
  4. White I. R. et al. Real-time multi-marker measurement of organic compounds in human breath: towards fingerprinting breath. J. Breath Res . 7, 017112 (2013). [DOI] [PubMed] [Google Scholar]
  5. Kohl I. et al. First observation of a potential non-invasive breath gas biomarker for kidney function. J. Breath Res . 7, 017110 (2013). [DOI] [PubMed] [Google Scholar]
  6. Fuchs P., Loeseken C., Schubert J. K. & Miekisch W. Breath gas aldehydes as biomarkers of lung cancer. Int. J. Cancer J. Int. Cancer 126, 2663–2670 (2010). [DOI] [PubMed] [Google Scholar]
  7. Alonso M., Castellanos M. & Sanchez J. M. Evaluation of potential breath biomarkers for active smoking: assessment of smoking habits. Anal. Bioanal. Chem. 396, 2987–2995 (2010). [DOI] [PubMed] [Google Scholar]
  8. Kamysek S. et al. Drug detection in breath: effects of pulmonary blood flow and cardiac output on propofol exhalation. Anal. Bioanal. Chem. 401, 2093–2102 (2011). [DOI] [PubMed] [Google Scholar]
  9. King J. et al. Isoprene and acetone concentration profiles during exercise on an ergometer. J. Breath Res . 3, 027006 (2009). [DOI] [PubMed] [Google Scholar]
  10. Morisco F. et al. Rapid ‘Breath-Print’ of Liver Cirrhosis by Proton Transfer Reaction Time-of-Flight Mass Spectrometry. A Pilot Study. PLoS ONE 8, e59658 (2013). [DOI] [PMC free article] [PubMed] [Google Scholar]
  11. Sukul P., Trefz P., Schubert J. K. & Miekisch W. Immediate effects of breath holding maneuvers onto composition of exhaled breath. J. Breath Res . 8, 037102 (2014). [DOI] [PubMed] [Google Scholar]
  12. Sukul P., Trefz P., Kamysek S., Schubert J. K. & Miekisch W. Instant effects of changing body positions on compositions of exhaled breath. J. Breath Res . 9, 047105 (2015). [DOI] [PubMed] [Google Scholar]
  13. Trefz P. et al. Continuous real time breath gas monitoring in the clinical environment by proton-transfer-reaction-time-of-flight-mass spectrometry. Anal. Chem. 85, 10321–10329 (2013). [DOI] [PubMed] [Google Scholar]
  14. Schwoebel H. et al. Phase-resolved real-time breath analysis during exercise by means of smart processing of PTR-MS data. Anal. Bioanal. Chem. 401, 2079–2091 (2011). [DOI] [PubMed] [Google Scholar]
  15. Schwarz K. et al. Breath acetone—aspects of normal physiology related to age and gender as determined in a PTR-MS study. J. Breath Res . 3, 027003 (2009). [DOI] [PubMed] [Google Scholar]
  16. King J. et al. Dynamic profiles of volatile organic compounds in exhaled breath as determined by a coupled PTR-MS/GC-MS study. Physiol. Meas. 31, 1169–1184 (2010). [DOI] [PubMed] [Google Scholar]
  17. King J. et al. A mathematical model for breath gas analysis of volatile organic compounds with special emphasis on acetone. J. Math. Biol. 63, 959–999 (2011). [DOI] [PubMed] [Google Scholar]
  18. King J. et al. A modeling-based evaluation of isothermal rebreathing for breath gas analyses of highly soluble volatile organic compounds. J. Breath Res . 6, 016005 (2012). [DOI] [PubMed] [Google Scholar]
  19. Klabunde R. Cardiovascular Physiology Concepts . (Lippincott Williams & Wilkins 2011). [Google Scholar]
  20. Klabunde R. Normal and Abnormal Blood Pressure . (Richard E. Klabunde 2013). [Google Scholar]
  21. Barbato A. L. In Clinical Methods: The History, Physical, and Laboratory Examinations (eds Walker H. K., Hall W. D. & Hurst J. W. ) (Butterworths 1990). [PubMed] [Google Scholar]
  22. Crystal G. J. & Salem M. R. The Bainbridge and the ‘reverse’ Bainbridge reflexes: history, physiology, and clinical relevance. Anesth. Analg. 114, 520–532 (2012). [DOI] [PubMed] [Google Scholar]
  23. Zach M. S. The physiology of forced expiration. Paediatr. Respir. Rev. 1, 36–39 (2000). [DOI] [PubMed] [Google Scholar]
  24. Stickland M. K. et al. Intra-pulmonary shunt and pulmonary gas exchange during exercise in humans. J. Physiol. 561, 321–329 (2004). [DOI] [PMC free article] [PubMed] [Google Scholar]
  25. Lovering A. T. et al. Intrapulmonary shunting and pulmonary gas exchange during normoxic and hypoxic exercise in healthy humans. J. Appl. Physiol. 104, 1418–1425 (2008). [DOI] [PubMed] [Google Scholar]
  26. Urden L. D., Stacy K. M. & Lough M. E. Priorities in Critical Care Nursing. (Elsevier Health Sciences 2015). [Google Scholar]
  27. Edwards A. D., Jennings S. J., Newstead C. G. & Wolff C. B. The effect of increased lung volume on the expiratory rate of rise of alveolar carbon dioxide tension in normal man. J. Physiol. 344, 81–88 (1983). [DOI] [PMC free article] [PubMed] [Google Scholar]
  28. Whipp B. J., Davis J. A. & Wasserman K. Ventilatory control of the ‘isocapnic buffering’ region in rapidly-incremental exercise. Respir. Physiol. 76, 357–367 (1989). [DOI] [PubMed] [Google Scholar]
  29. Paiva M., van Muylem A., Ravez P. & Yernault J. C. Inspired volume dependence of the slope of the alveolar plateau. Respir. Physiol. 56, 309–325 (1984). [DOI] [PubMed] [Google Scholar]
  30. Schmidt R. F. & Thews G. Human Physiology . (Springer Science & Business Media 2013). [Google Scholar]
  31. Ferguson G. T. Why Does the Lung Hyperinflate? Proc. Am. Thorac. Soc . 3, 176–179 (2006). [DOI] [PubMed] [Google Scholar]
  32. Kalapos M. P. On the mammalian acetone metabolism: from chemistry to clinical implications. Biochim. Biophys. Acta 1621, 122–139 (2003). [DOI] [PubMed] [Google Scholar]
  33. Roca J. & Wagner P. D. Contribution of multiple inert gas elimination technique to pulmonary medicine. 1. Principles and information content of the multiple inert gas elimination technique. Thorax 49, 815–824 (1994). [DOI] [PMC free article] [PubMed] [Google Scholar]
  34. Wagner P. D. The multiple inert gas elimination technique (MIGET). Intensive Care Med. 34, 994–1001 (2008). [DOI] [PubMed] [Google Scholar]
  35. Anderson J. C. & Hlastala M. P. Impact of airway gas exchange on the multiple inert gas elimination technique: theory. Ann. Biomed. Eng. 38, 1017–1030 (2010). [DOI] [PMC free article] [PubMed] [Google Scholar]
  36. Anderson J. C. & Hlastala M. P. Breath tests and airway gas exchange. Pulm. Pharmacol. Ther. 20, 112–117 (2007). [DOI] [PubMed] [Google Scholar]
  37. Anderson J. C., Babb A. L. & Hlastala M. P. Modeling soluble gas exchange in the airways and alveoli. Ann. Biomed. Eng. 31, 1402–1422 (2003). [DOI] [PubMed] [Google Scholar]
  38. Anderson J. C., Lamm W. J. E. & Hlastala M. P. Measuring airway exchange of endogenous acetone using a single-exhalation breathing maneuver. J. Appl. Physiol. Bethesda Md 1985 100, 880–889 (2006). [DOI] [PubMed] [Google Scholar]
  39. Stone B. G., Besse T. J., Duane W. C., Evans C. D. & DeMaster E. G. Effect of regulating cholesterol biosynthesis on breath isoprene excretion in men. Lipids 28, 705–708 (1993). [DOI] [PubMed] [Google Scholar]
  40. Filipiak W. et al. Dependence of exhaled breath composition on exogenous factors, smoking habits and exposure to air pollutants. J. Breath Res . 6, (2012). [DOI] [PMC free article] [PubMed] [Google Scholar]
  41. Smith L. J. et al. Spirometry guidelines influence lung function results in a longitudinal study of young adults. Respir. Med. 104, 858–864 (2010). [DOI] [PMC free article] [PubMed] [Google Scholar]
  42. Henschen M., Stocks J., Hoo A.-F. & Dixon P. Analysis of forced expiratory maneuvers from raised lung volumes in preterm infants. J. Appl. Physiol. 85, 1989–1997 (1998). [DOI] [PubMed] [Google Scholar]
  43. Miller M. R. et al. Standardisation of spirometry. Eur. Respir. J. 26, 319–338 (2005). [DOI] [PubMed] [Google Scholar]
  44. Spruit M. A. et al. An official American Thoracic Society/European Respiratory Society statement: key concepts and advances in pulmonary rehabilitation. Am. J. Respir. Crit. Care Med. 188, e13–64 (2013). [DOI] [PubMed] [Google Scholar]
  45. Nathell L., Nathell M., Malmberg P. & Larsson K. COPD diagnosis related to different guidelines and spirometry techniques. Respir. Res. 8, 89 (2007). [DOI] [PMC free article] [PubMed] [Google Scholar]
  46. Chronic obstructive pulmonary disease in over 16s: diagnosis and management | Guidance and guidelines | NICE. Available at: http://www.nice.org.uk/guidance/CG101. (Accessed: 9th December 2015)
  47. Swanney M. P. et al. Using the lower limit of normal for the FEV1/FVC ratio reduces the misclassification of airway obstruction. Thorax 63, 1046–1051 (2008). [DOI] [PubMed] [Google Scholar]
  48. Hannink J. et al. Validity of Oxycon Mobile in measuring inspiratory capacity in healthy subjects. Clin. Physiol. Funct. Imaging 30, 206–209 (2010). [DOI] [PubMed] [Google Scholar]
  49. Akkermans M. A., Sillen M. J. H., Wouters E. F. M. & Spruit M. A. Validation of The Oxycon Mobile Metabolic System in Healthy Subjects. J. Sports Sci. Med . 11, 182–183 (2012). [PMC free article] [PubMed] [Google Scholar]
  50. Perret C. & Mueller G. Validation of a new portable ergospirometric device (Oxycon Mobile) during exercise. Int. J. Sports Med. 27, 363–367 (2006). [DOI] [PubMed] [Google Scholar]
  51. Rosdahl H., Gullstrand L., Salier-Eriksson J., Johansson P. & Schantz P. Evaluation of the Oxycon Mobile metabolic system against the Douglas bag method. Eur. J. Appl. Physiol. 109, 159–171 (2010). [DOI] [PubMed] [Google Scholar]
  52. Broch O. et al. A comparison of the Nexfin (R) and transcardiopulmonary thermodilution to estimate cardiac output during coronary artery surgery. Anaesthesia 67, 377–383 (2012). [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplementary Information
srep28029-s1.pdf (282.4KB, pdf)

Articles from Scientific Reports are provided here courtesy of Nature Publishing Group

RESOURCES