Skip to main content
. Author manuscript; available in PMC: 2016 Dec 10.
Published in final edited form as: J Chem Eng Data. 2015 Nov 17;60(12):3496–3505. doi: 10.1021/acs.jced.5b00752

Table 3.

The thermal penetration depth, δz ≡ (4DTt)1/2, and the transient pressure drop ΔP associated with the cooling caused by one pumping cycle, during which the sample tube is opened to an evacuated manifold of volume V2. The calculation used Eq. (9), Eq. (10), and the values for liquid naphthalene at 80 °C (Table 2).

t(s) δz (mm) ΔP/PV
1   0.05 0.14
10   1.5 0.04
100 4.7 0.014