Skip to main content
. 2016 Mar 29;23:12835–12866. doi: 10.1007/s11356-016-6503-x

Table 4.

DCF, E2, and EE2 concentrations in influent and effluents and the removal efficiency by conventional wastewater treatment in Europe since 2002. During secondary treatment, diclofenac had moderate removal rates in different WWTPs in Europe. The removal rates are different, depending on various influences

Compound/WWTP/country Concentration (μg L−1) Removal efficiency (%) Reference
Influent Effluent
DCF
 Not described, Germany 3.02a 2.51a 17 Heberer (2002b)
 Conventional WWTP, France, Greece, Italy 0.68a Andreozzi et al. (2003)
 Conventional WWTP, UK 0.41–0.46 Hilton and Thomas (2004)
 4 conventional WWTPs, UK 0.599b (0.424a) Ashton et al. (2004)
 Conventional WWTP, Germany 2.3b 1.6b 30 Quintana and Reemtsma (2004)
 3 conventional WWTPs (1–3) with preliminary clarification WWTP1 (3 samplings): 3.19–4.11 WWTP1 (3 samplings): 1.53–1.68 WWTP1 (3 samplings): 47–62 Clara et al. (2005)
 2 aeration tanks, final clarification, Austria WWTP2: 1.40 WWTP2: 1.30 WWTP2: 7
WWTP3: 0.90 WWTP3: 0.78 WWTP3: 14
 Conventional WWTP, Sweden 0.16 0.12 25 Bendz et al. (2005)
 Pilot-scale membrane bioreactor (in 3 sampling periods 3.19–4.11c 2.03–3.46c −6.6d to 50.6 Clara et al. (2005)
 Conventional WWTP, pilot-scale membrane or fixed bed reactor, Switzerland 20–40 Joss et al. (2005)
 3 conventional WWTPs in EU with secondary or tertiary treatments <5 Reemtsma et al.(2006)
 Different conventional WWTP, Spain, Belgium, Germany, and Slovenia 0.021–0.148c 0.032–1.42c Hernando et al. (2006)
 5 conventional WWTPs, Croatia 250a 215a 14 Gros et al. (2006b)
0.21–0.49c Rabiet et al. (2006)
 Conventional WWTP, Finland 0.42a (0.46a) 0.32b (0.35a) 24 Vieno (2007)
 Conventional WWTP, Norway 295a 259a 13 Thomas et al. (2007)
 Hospital Ulleval, Norway 784a Thomas et al. (2007)
 Hospital Rijkshospitalet, Norway 1550a Thomas et al. (2007)
 29 WWTPs, municipal and industrial in Bosnia-Herzegovina, Croatia, Serbia 0.859b Terzić et al. (2008)
 Conventional WWTP, Sweden, municipal and hospital wastewater 0.23b 0.49b −105 Zorita et al. (2009)
 WWTP Cilfynydd, Wales, UK: biological treatment-trickling filter beds 0.07 0.12 −71d Kasprzyk-Hordern et al. (2008)
 7 conventional WWTPs, Spain 30–100 Gros et al. (2007)
 Conventional WWTP, Greece 0.86–2.17c 0.15–1.1c
0.41b
Samaras et al. (2013)
 Conventional WWTP, Spain with influent of wastewater from 4 hospitals and municipal wastewater 0.0670b 0.043 38 Santos et al. (2013)
 Conventional WWTP, Switzerland 1.197b 1.187b 9 Margot et al. (2013)
 8 conventional WWTPs, Greece 0.28b 0.11b 70 Kosma et al. (2014)
 Conventional WWTP, Spain, industrial/municipal wastewater 0.288 0.309 <1 Collado et al. (2014)
 Conventional WWTP, France
(a) total nitrification + post denitrification; (b) partial nitrification, no denitrification
(a) 184b
(b) 384b
(a) 52b
(b) 171b
(a) 72b
(b) 55b
Mailler et al. (2014)
0.049b/0.043a Loos et al. (2013)
E2
 Conventional WWTP, Norway 12a <3a 75 Thomas et al. (2007)
 Hospital Ulleval, Norway 28a Thomas et al. (2007)
 Hospital Rijkshospitalet, Norway 41a Thomas et al. (2007)
 Conventional WWTP, Europe 25.7b
21.5a
1.9b
1.0a
Janex-Habibi et al. (2009)
EE2
 Conventional WWTP, Norway <0.3a <0.3a Thomas et al. (2007)
 Hospital Ulleval, Norway <0.3a Thomas et al. (2007)
 Hospital Rijkshospitalet, Norway <0.3a Thomas et al. (2007)
 Conventional WWTP, France 1.6b
1.0a
0.9b
0.5a
Janex-Habibi et al. (2009)

aMedian

bMean

cMin–max

dIncrease of the effluent concentration relative to the influent concentration