Table 4.
DCF, E2, and EE2 concentrations in influent and effluents and the removal efficiency by conventional wastewater treatment in Europe since 2002. During secondary treatment, diclofenac had moderate removal rates in different WWTPs in Europe. The removal rates are different, depending on various influences
| Compound/WWTP/country | Concentration (μg L−1) | Removal efficiency (%) | Reference | |
|---|---|---|---|---|
| Influent | Effluent | |||
| DCF | ||||
| Not described, Germany | 3.02a | 2.51a | 17 | Heberer (2002b) |
| Conventional WWTP, France, Greece, Italy | – | 0.68a | – | Andreozzi et al. (2003) |
| Conventional WWTP, UK | – | 0.41–0.46 | – | Hilton and Thomas (2004) |
| 4 conventional WWTPs, UK | – | 0.599b (0.424a) | – | Ashton et al. (2004) |
| Conventional WWTP, Germany | 2.3b | 1.6b | 30 | Quintana and Reemtsma (2004) |
| 3 conventional WWTPs (1–3) with preliminary clarification | WWTP1 (3 samplings): 3.19–4.11 | WWTP1 (3 samplings): 1.53–1.68 | WWTP1 (3 samplings): 47–62 | Clara et al. (2005) |
| 2 aeration tanks, final clarification, Austria | WWTP2: 1.40 | WWTP2: 1.30 | WWTP2: 7 | |
| WWTP3: 0.90 | WWTP3: 0.78 | WWTP3: 14 | ||
| Conventional WWTP, Sweden | 0.16 | 0.12 | 25 | Bendz et al. (2005) |
| Pilot-scale membrane bioreactor (in 3 sampling periods | 3.19–4.11c | 2.03–3.46c | −6.6d to 50.6 | Clara et al. (2005) |
| Conventional WWTP, pilot-scale membrane or fixed bed reactor, Switzerland | – | – | 20–40 | Joss et al. (2005) |
| 3 conventional WWTPs in EU with secondary or tertiary treatments | – | – | <5 | Reemtsma et al.(2006) |
| Different conventional WWTP, Spain, Belgium, Germany, and Slovenia | 0.021–0.148c | 0.032–1.42c | – | Hernando et al. (2006) |
| 5 conventional WWTPs, Croatia | 250a | 215a | 14 | Gros et al. (2006b) |
| – | 0.21–0.49c | – | Rabiet et al. (2006) | |
| Conventional WWTP, Finland | 0.42a (0.46a) | 0.32b (0.35a) | 24 | Vieno (2007) |
| Conventional WWTP, Norway | 295a | 259a | 13 | Thomas et al. (2007) |
| Hospital Ulleval, Norway | 784a | Thomas et al. (2007) | ||
| Hospital Rijkshospitalet, Norway | 1550a | Thomas et al. (2007) | ||
| 29 WWTPs, municipal and industrial in Bosnia-Herzegovina, Croatia, Serbia | 0.859b | Terzić et al. (2008) | ||
| Conventional WWTP, Sweden, municipal and hospital wastewater | 0.23b | 0.49b | −105 | Zorita et al. (2009) |
| WWTP Cilfynydd, Wales, UK: biological treatment-trickling filter beds | 0.07 | 0.12 | −71d | Kasprzyk-Hordern et al. (2008) |
| 7 conventional WWTPs, Spain | 30–100 | Gros et al. (2007) | ||
| Conventional WWTP, Greece | 0.86–2.17c | 0.15–1.1c
0.41b |
– | Samaras et al. (2013) |
| Conventional WWTP, Spain with influent of wastewater from 4 hospitals and municipal wastewater | 0.0670b | 0.043 | 38 | Santos et al. (2013) |
| Conventional WWTP, Switzerland | 1.197b | 1.187b | 9 | Margot et al. (2013) |
| 8 conventional WWTPs, Greece | 0.28b | 0.11b | 70 | Kosma et al. (2014) |
| Conventional WWTP, Spain, industrial/municipal wastewater | 0.288 | 0.309 | <1 | Collado et al. (2014) |
| Conventional WWTP, France (a) total nitrification + post denitrification; (b) partial nitrification, no denitrification |
(a) 184b
(b) 384b |
(a) 52b
(b) 171b |
(a) 72b
(b) 55b |
Mailler et al. (2014) |
| 0.049b/0.043a | Loos et al. (2013) | |||
| E2 | ||||
| Conventional WWTP, Norway | 12a | <3a | 75 | Thomas et al. (2007) |
| Hospital Ulleval, Norway | 28a | Thomas et al. (2007) | ||
| Hospital Rijkshospitalet, Norway | 41a | Thomas et al. (2007) | ||
| Conventional WWTP, Europe | 25.7b
21.5a |
1.9b
1.0a |
Janex-Habibi et al. (2009) | |
| EE2 | ||||
| Conventional WWTP, Norway | <0.3a | <0.3a | Thomas et al. (2007) | |
| Hospital Ulleval, Norway | <0.3a | Thomas et al. (2007) | ||
| Hospital Rijkshospitalet, Norway | <0.3a | Thomas et al. (2007) | ||
| Conventional WWTP, France | 1.6b
1.0a |
0.9b
0.5a |
Janex-Habibi et al. (2009) | |
aMedian
bMean
cMin–max
dIncrease of the effluent concentration relative to the influent concentration