Table 1.
Accuracy of knee contact force predictions for the two approaches. Accuracy was quantified using mean ± standard deviation of MeanD, R2, RMSE, and r values for each approach relative to the experimental measurements. Statistically significant differences (p < 0.05) in each quantity are indicated by an asterisk (*).
Quantity | Approach | Medial | Lateral | Total |
---|---|---|---|---|
MeanD (N) | A | −0.3 ± 12.4* | 1.3 ± 20.4* | 1.1 ± 23.3* |
B | 223.6 ± 45.5* | 145.1 ± 44.7* | 368.7 ± 65.7* | |
R2 | A | 0.97 ± 0.01* | 0.88 ± 0.05* | 0.96 ± 0.02* |
B | 0.10 ± 0.28* | −3.43 ± 1.74* | −0.36 ± 0.24* | |
RMSE (N) | A | 52.6 ± 16.4* | 56.6 ± 9.5* | 92.8 ± 26.0* |
B | 322.8 ± 63.9* | 347.8 ± 33.1* | 559.9 ± 32.1* | |
r | A | 0.99 ± 0.01* | 0.95 ± 0.02* | 0.98 ± 0.01* |
B | 0.90 ± 0.03* | −0.10 ± 0.10* | 0.74 ± 0.07* |