Skip to main content
. 2016 Jun 13;138(8):0810011–08100111. doi: 10.1115/1.4033673

Table 1.

Accuracy of knee contact force predictions for the two approaches. Accuracy was quantified using mean ± standard deviation of MeanD, R2, RMSE, and r values for each approach relative to the experimental measurements. Statistically significant differences (p < 0.05) in each quantity are indicated by an asterisk (*).

Quantity Approach Medial Lateral Total
MeanD (N) A −0.3 ± 12.4* 1.3 ± 20.4* 1.1 ± 23.3*
B 223.6 ± 45.5* 145.1 ± 44.7* 368.7 ± 65.7*
R2 A 0.97 ± 0.01* 0.88 ± 0.05* 0.96 ± 0.02*
B 0.10 ± 0.28* −3.43 ± 1.74* −0.36 ± 0.24*
RMSE (N) A 52.6 ± 16.4* 56.6 ± 9.5* 92.8 ± 26.0*
B 322.8 ± 63.9* 347.8 ± 33.1* 559.9 ± 32.1*
r A 0.99 ± 0.01* 0.95 ± 0.02* 0.98 ± 0.01*
B 0.90 ± 0.03* −0.10 ± 0.10* 0.74 ± 0.07*