. 2016 May 9;39(6):531–541. doi: 10.1111/pace.12854

Table I.

Baseline Demographics, Device Settings, and CRT Response

Demographics
Pre‐CRT implantation
Mean age (years) 70 ± 7
Male 9 (100%)
Sinus rhythm 6 (67%)
Ischemic heart disease 7 (78%)
QRS duration (ms) 152 ± 37
LBBB morphology 9 (100%)
NYHA class III 7 (78%)
LV systolic function, EF by echo (%) 30 ± 8
RV systolic function: TAPSE (mm) 13 ± 4
RV basal diameter, diastole (mm) 41 ± 8
RV systolic function, EF by MRI (%) 43 ± 10
CRT settings
Sensed AV delay (ms) 120 ± 22
Paced AV delay (ms) 135 ± 15
VV timing: LV ahead (ms) 17 ± 13
CRT response assessment at 6 months
LV systolic function, EF by echo (%) 32 ± 11
RV systolic function: TAPSE (mm) 14 ± 2
RV basal diameter, diastole (mm) 39 ± 10
Echo responder 3 (33%)
Clinical responder 5 (56%)

Averaged data are mean ± SD.

AV = atrio‐ventricular; CRT = cardiac resynchronization therapy; ECHO = echocardiography; EF = ejection fraction; LBBB = left bundle branch block; LV = left ventricular; MRI = magnetic resonance imaging; NYHA = New York Heart Association; RV = right ventricular; TAPSE = Tricuspid Annular Plane Systolic Excursion; VV = ventricular‐ventricular.