Skip to main content
. 2016 Jun 23;17:250. doi: 10.1186/s12859-016-1080-z

Table 5.

Overall performance measured on all single drugs and outcomes in OMOP gold standard

GEA 7–10 4.5–7 1–5.5 2nd level
 Threshold 0.1 0.05 0.005 0.1 0.05 0.005 0.1 0.05 0.005 0.1 0.05 0.005
TP 121 119 113 112 110 100 116 113 104 116 115 102
TN 182 188 205 191 195 205 159 164 178 186 193 198
FP 33 27 10 24 20 10 56 51 37 29 22 17
FN 38 40 46 47 49 59 43 46 55 43 44 57
Precision 0.79 0.82 0.92 0.82 0.85 0.91 0.67 0.69 0.74 0.80 0.84 0.86
Recall 0.76 0.75 0.71 0.70 0.69 0.63 0.73 0.71 0.65 0.73 0.72 0.64
F1-Measure 0.77 0.78 0.80 0.76 0.76 0.74 0.70 0.70 0.69 0.76 0.78 0.73
PRR 7–10 4.5–7 1–5.5 2nd level
 Threshold 1 1.5 5 1 1.5 5 1 1.5 5 1 1.5 5
TP 112 96 48 110 93 39 111 83 6 109 90 27
TN 126 144 197 150 172 208 152 176 211 166 184 211
FP 89 71 18 65 43 7 63 39 4 49 31 4
FN 47 63 111 49 66 120 48 76 153 50 69 132
Precision 0.56 0.57 0.73 0.63 0.68 0.85 0.64 0.68 0.60 0.69 0.74 0.87
Recall 0.70 0.60 0.30 0.69 0.58 0.25 0.70 0.52 0.04 0.69 0.57 0.17
F1-Measure 0.62 0.59 0.43 0.66 0.63 0.38 0.67 0.59 0.07 0.69 0.64 0.28

Performance with GEA (top) and PRR (bottom) using different abstraction levels and thresholds. Bold numbers indicate best performance throughout all configurations (individually for GEA and PRR-based configurations)