Skip to main content
. 2016 Jan-Feb;18(80):26–35. doi: 10.4103/1463-1741.174377

Table 4.

Speech Intelligibility Index (SII) and Articulation Index (AI) measures made in three patient rooms on the standard unit in three acoustic conditions: No curtain, standard curtain, and Hush Curtain®

Refurbished unit two
-bed-occupied room “F”
No curtain Standard curtain Hush Curtain®



SII AI SII AI SII AI
Doorway 0.581 0.487 0.553 0.454
2nd patient bed 0.536 0.428 0.503 0.389
Hallway 0.357 0.241 0.442 0.333
Patient to nurse station 0.009 0.000 0.010 0.000
Nurse station to patient 0.146 0.039 0.131 0.034
Two-bed-unoccupied
Room “G”
 Doorway 0.706 0.639 0.674 0.597 0.511 0.404
 2nd patient bed 0.592 0.492 0.570 0.470 0.375 0.264
 Hallway 0.501 0.408 0.468 0.366 0.378 0.263
 Patient to nurse station 0.020 0.003 0.019 0.001 0.010 0.000
 Nurse station to patient 0.193 0.075 0.172 0.061 0.115 0.033
One-bed-unoccupied
Room “H”
 Doorway 0.644 0.559 0.614 0.523 0.612 0.521
 Hallway 0.449 0.328 0.403 0.278 0.394 0.266
 Patient to nurse station 0.262 0.149 0.249 0.136 0.203 0.092
 Nurse station to patient 0.274 0.150 0.261 0.135 0.215 0.096