Skip to main content
. Author manuscript; available in PMC: 2016 Jun 23.
Published in final edited form as: Chemosensors (Basel). 2015 Dec 11;3(4):284–294. doi: 10.3390/chemosensors3040284

Table 3.

Selectivity coefficients (−logKHPO4,J) as a function of lipophilicity for 13 interferents.

Plast. logKLipo Cl NO3 I F Cit3 SO42− SCN Ace Lac BTP B-T Br HEPES
DMF −0.6 1.88 1.08 1.16 0.55 −0.75 0.07 0.59 0.87 0.84 0.35 0.98 0.46 1.11
NPOE 2.3 2.46 1.63 2.30 1.17 −0.55 0.56 1.19 1.63 1.65 0.98 1.65 1.19 1.76
DBP 3.6 3.41 2.42 2.00 2.87 −0.54 0.93 2.00 3.41 3.19 1.11 3.35 0.33 2.95
TEHP 4.4 2.74 2.33 2.24 1.12 −0.58 0.51 1.26 1.70 1.79 1.35 2.09 0.98 1.65
DBS 4.6 2.46 1.77 2.01 1.05 −0.58 1.07 1.48 1.98 2.03 1.45 2.17 1.23 1.97
BEHS 6.9 2.49 2.31 2.38 1.13 −0.57 0.52 1.40 1.91 1.96 1.41 2.16 1.17 1.74