Skip to main content
. 2004 Aug;70(8):4621–4628. doi: 10.1128/AEM.70.8.4621-4628.2004

TABLE 4.

Degradation pattern of sodium benzoate in different biodegradation test systemsa

Test system/parameterb Sapromat
Oxitop
CO2 evolution test
MCBTS
Oxygen consumption
CO2 production
Biodegradation (%) μmax (day−1) Biodegradation (%) μmax (day−1) Biodegradation (%) μmax (day−1) Biodegradation (%) μmax (day−1) Biodegradation (%) μmax (day−1)
Mean 85.0 1.5 89.5 2.8 93.0 1.1 78.5 2.9 78.4 2.1
CV (%) 3.6 7.2 2.9 19.2 10.2 9.6 4.2 13.9 9.4 48.2
95% CIM 81.9-89.7 1.3-1.6 86.8-92.2 2.2-3.3 77.8-100 1.0-1.3 73.2-83.3 2.2-3.5 72.2-84.6 1.2-2.9
a

The test period was 28 days. The number of tests performed was 4 to 6. The lag period varied between 0.8 and 1.5 days.

b

CV, coefficient of variation; CIM, confidence interval of the mean.