Table 3.

Absolute surface errors with healthy anatomy and WM lesions with MaCRUISE+ (mean ± standard deviation in mm).

Landmarks FreeSurfer Corrected FreeSurfer* CRUISE+ MaCRUISE+
Healthy Anatomy Rater A Outer Surface 0.445 ± 0.394 0.433 ± 0.339 0.509 ± 0.490 0.529 ± 0.496
Inner Surface 0.572 ± 0.471 0.511 ± 0.420 0.482 ± 0.455 0.485 ± 0.510

Rater B Outer Surface 0.778 ± 1.605 0.600 ± 0.976 0.518 ± 0.539 0.624 ± 0.698
Inner Surface 0.423 ± 0.326 0.411 ± 0.302 0.368 ± 0.340 0.390 ± 0.354

Near WM Lesions Rater A Outer Surface 0.858 ± 1.588 0.679 ± 1.009 0.551 ± 0.566 0.670 ± 0.808
Inner Surface 0.536 ± 0.488 0.494 ± 0.407 0.337 ± 0.283 0.368 ± 0.293

Rater B Outer Surface 0.874 ± 1.498 0.735 ± 1.043 0.589 ± 0.599 0.682 ± 0.755
Inner Surface 0.476 ± 0.564 0.446 ± 0.551 0.425 ± 0.315 0.387 ± 0.340

Rater C Outer Surface 1.028 ± 1.270 0.874 ± 0.878 0.641 ± 0.553 0.705 ± 0.699
Inner Surface 0.707 ± 0.530 0.696 ± 0.588 0.410 ± 0.293 0.447 ± 0.322
*

FreeSurfer after correction with the WM lesion masks generated by Lesion-TOADS.