Skip to main content
. 2016 Jun 29;11:314. doi: 10.1186/s11671-016-1537-z

Table 1.

MAPLE deposition parameters

Sample C36 C37 C46 C47
1st MAPLE deposition
 Guest OLC-DOX OLC-DOX UDD-DOX UDD-DOX
 Matrix Saline solution 7.2 mg NaCl/1.0 ml H2O Saline solution 7.2 mg NaCl/1.0 ml H2O Water Water
 Target 10 mg guest/1.0 ml matrix 10 mg guest/1.0 ml matrix 10 mg guest/1.0 ml matrix 10 mg guest/1.0 ml matrix
 Pulse energy 102 mJ/pulse 102 mJ/pulse 191 mJ/pulse 123 mJ/pulse
 Number of pulses 4400 pulses 4400 pulses 8800 pulses 8800 pulses
 Target to substrate 18 mm 10 mm 18 mm 10 mm
2nd MAPLE deposition
 Guest Monoclonal rabbit anti-EGFR (clone SP9, RMPD 020, Diagnostic BioSystems, USA) Monoclonal mouse anti-EGF (clone 2 F1, WH0001950M1, Sigma, USA) Monoclonal rabbit anti-EGFR (clone SP9, RMPD 020, Diagnostic BioSystems, USA) Monoclonal mouse anti-EGF (clone 2 F1, WH0001950M1, Sigma, USA)
 Matrix Saline solution 9.0 mg NaCl/1.0 ml H2O Saline solution 9.0 mg NaCl/1.0 ml H2O Saline solution 9.0 mg NaCl/1.0 ml H2O Saline solution 9.0 mg NaCl/1.0 ml H2O
 Target 2.0 ml guest/8.0 ml matrix 2.0 ml guest/8.0 ml matrix 2.0 ml guest/8.0 ml matrix 2.0 ml guest/8.0 ml matrix
 Pulse energy 263 mJ/pulse 191 mJ/pulse 360 mJ/pulse 191 mJ/pulse
 Number of pulses 8800 pulses 4400 pulses 8800 pulses 4400 pulses
 Target to substrate 18 mm 10 mm 18 mm 10 mm
Both MAPLE depositions
 Target scanned area 1.7 cm2 1.7 cm2 1.7 cm2 1.7 cm2
 Laser type Q-switched Q-switched Q-switched Q-switched
Nd:YAG Nd:YAG Nd:YAG Nd:YAG
 Laser wavelength 1064 nm 1064 nm 1064 nm 1064 nm
 Pulse duration 10 ns 10 ns 10 ns 10 ns
 Pulse repetition rate 4 pulses/s 4 pulses/s 4 pulses/s 4 pulses/s
 Spot size (elliptical) 1.0 mm × 1.4 mm 1.0 mm × 1.4 mm 1.0 mm × 1.4 mm 1.0 mm × 1.4 mm
 Target temperature 145 K 145 K 145 K 145 K
 Chamber pressure 10−4 Pa 10−4 Pa 10−4 Pa 10−4 Pa