Experimental results of original data set of EEG signals.

IG SFS SFFS NRFS
Number of Selected Feature Vectors 8 5 6 11
Accuracy of Testing Data (%) 89.26 91.85 93.33 94.81
Computational Time (s) 1.2 0.6 2.8 42.5