Skip to main content
. 2015 Dec 11;27(5):542–550. doi: 10.1097/MBC.0000000000000453

Table 2.

Comparison of D-dimer concentrations in the blood of representative patients with different diseases measured by D-dimer assays utilizing antibodies with different specificities

Patient diagnosis FDP/DD ratio measured by the DD189-DD255 assay DD measured by the DD162-DD186 assay, μg/ml DD measured by the DD189-DD255 assay, μg/ml
Deep vein thrombosis 2.7 420 4.8
Deep vein thrombosis 3.5 >1000 6
Surgical operation 0.32 65 3.3
Sepsis 0.36 145 4.6

FDP, fibrin degradation product.