Skip to main content
. Author manuscript; available in PMC: 2017 Jun 1.
Published in final edited form as: J AAPOS. 2016 May 6;20(3):214–219. doi: 10.1016/j.jaapos.2016.01.016

Table 4.

Image quality in the first 6 months and last 6 months of the imaging period

First 6 monthsa Last 6 monthsa

Image view N Acceptable Poor Missing N Acceptable Poor Missing P value
Pupil size 1860 1763 (95%) 66 (4%) 31 (2%) 2007 1874 (93%) 109 (5%) 24 (1%) 0.01
Posterior pole 1789 (96%) 37 (2%) 34 (2%) 1932 (96%) 59 (3%) 16 (1%) 0.003
Nasal retina 1519 (82%) 256 (14%) 85 (5%) 1713 (85%) 248 (12%) 46 (2%) <0.001
Temporal retina 1774 (95%) 49 (3%) 37 (2%) 1935 (96%) 55 (3%) 17 (1%) 0.01
Inferior retina 1650 (89%) 100 (5%) 110 (6%) 1881 (94%) 76 (4%) 50 (2%) <0.001
Superior retina 1736 (93%) 87 (5%) 37 (2%) 1858 (93%) 103 (5%) 46 (2%) 0.64
All retinal images 8468 (91%) 529 (6%) 303 (3%) 9319 (93%) 541 (5%) 175 (2%) 0.02
a

The first 6 months and the last 6 months is center specific, depending on when they start imaging and stop imaging.